TANDBERG 3000 MXP User Manual
62
4.1.5 Max Call Length
This feature will automatically end both incoming and outgoing calls when the call time
exceeds the specified Max Call Length. Max Call Length can have the following values: 0-999
(minutes), where 0 means off.
4.1.6 Global Phone Book Settings
Global
On Global Phone Book is available in the menu.
Off Global Phone Book is hidden from the menu and is unavailable for users.
IP address
Enter the IP address of the management system that provides the Phone Book.
Path
The Path indicates the function of the management system.
4.1.7 Permissions
Permissions contains settings for incoming MCU Calls, incoming telephone Calls, Far End
Control and Fallback to Telephony.
Incoming MCU Calls
On When you are in a call, the system will provide visual and audible indications of
an incoming call and ask you to accept/reject the call.
Off The system will not accept incoming calls when you are in a call.
Incoming Telephone Calls
On The system will accept incoming telephone calls.
Off The system will not accept incoming telephone calls. This is useful to prevent
incoming calls from systems other than videoconferencing systems.