16
Operating Procedures Model104
Pour the sanitizing solution into the funnel and allow it
to flow into the freezing cylinder.
Figure 23
Step 3
Putt he control switch into the EJECT posit ion. This will
cause the sanitizing solution in the freezing cy linder to
be agitated. Allow it to agitate for five minutes .
KEEP FINGERS OUT OF FILL AND
DISCHARGE OPENINGS! Failure to do so may result
in personal injury or component damage.
Figure 24
Step 4
Put the control switch into the OFF position. Holding a
mix pail beneath the ejection port, open the draw arm
and drain the sanitizing solution from t he freezing
cylinder. Close the draw arm.
Figure 25
PrimingStep 1
With the control switch in the OF F position, hold an
empty mix pail beneath the ejection port and open the
draw arm.
KEEP FINGERS OUT OF FILL AND
DISCHARGE OPENINGS! Failure to do so may result
in personal injury or component damage.
Step 2
Pour the desired amount of mix directly through the
funnel. The mix in the freezing cylinder will force out
any remaining sanitizing solution. When full strengt h
mix is flowing from the ejection port, clos e the draw
arm.
Figure 26