12
Important: Tothe Operator Model432
Indicator Light - “Mix Out” (Item 4)
A mix out indicating light is located on the front of the
machine. When the light isf lashing, it indicates that the
hopper is empty and the mix supply needs
replenishing. To prevent damage to the unit,
refrigeration discontinues automatically when the mix
outindicat or lights illuminates. Refrigeration will restart
30 seconds after the mix supply is replenished.
Indicator Light - “Add Mix” (Item 5)
A mix level indicating light is located on the front ofthe
machine. When the light isf lashing, it indicates that the
mix hopper has a low supply of product and should be
refilled as soon as possible.
Viscosity Adjustment (Item 6)
The viscosity (thickness) of the slush can be adjusted
by turning the viscosity adjustment screw located
under the control channel. Turn the viscosity
adjustment screw clockwise for a t hicker product, or
counterclockwise for a thinner product. After mak ing
an adjustment, allowt herefrigeration system to cycle
2 or 3 times to accurately evaluate the viscosity.