TC electronic SDN BHD SDN BHD Makeup Gain, Meters, Multi-Bandmode, Edit Menu, Bypass, Level

Models: SDN BHD

1 31
Download 31 pages 26.25 Kb
Page 19
Image 19
Makeup Gain

MULTI-BAND MODE

Makeup Gain

Bypass

Press to bypass the TRIPLE•C. All processing parameters are bypassed. Input level control and all system settings found in the I/O menu are not bypassed.

Level

When a signal is compressed the max Output level of the signal is reduced. Since it is a reduction in dynamic content and not a gain-reduction that is the object of applying compression a make-up gain is necessary to lift the signal to appropriate level. Observe the gain reduction via the meters and lift the processed signal to approx. 0dB using the Level knob in the Make Up Gain section.

For detailed information please read the section on make up gain in the section called “Using Compression”.

Edit Menu

To enter the Edit menu.

Press MENU.

Use the VALUE SET wheel to select the Edit menu and press ENTER.

Comp Style

Various predefined Compression Styles can be selected. Evaluate the Source material and choose appropriate style.

DRG - Digital Radiance Generator

Range: 0 -10

With this parameter you can add second harmonic distortion. This is a commonly used tube-simulation that will add warmth to the signal.

Hi X-Over

Range: 20Hz to 20kHz

Sets the Hi Frequency Cross-over point.

Lo X-Over

Range: 20Hz to 20kHz

Sets the Lo Frequency Cross-over point.

Cross-over Freq - illustration.

External Sidechain

Range: Off, On, Add

Determines how the TRIPLE•C should respond to the signal present on the External Sidechain.

Off

: This is the ”Normal” setting. The TRIPLE•C will

 

only respond to the Input signal and not to any

 

signal present on the Sidechain.

On

: The compression will be controlled only by the

 

signal present on the Sidechain Input.

Add

: In this mode the TRIPLE•C will respond both to

 

the Input signal and to the signal present on the

 

Sidechain. The Input signal and the Sidechain

 

signal are added for compression control.

 

Please note that the signal present on the

 

Sidechain Input under no circumstances is

 

passed to the Outputs. The Sidechain Input is

 

only for compression control.

Meters

In Multi-band mode the meters indicates the applied compression in both the Lo, Mid, and Hi bands.