Appendix A Performance Specification

The specification tables use the following abbreviations:Performance Requirement (Req). All

performance requirements in the specification tables are identified with Req, and can be assured by completing the Performance Check Procedure (1740A/ 1750A/1760-Series Service Manual.) Allow a warm-up time of 20 minutes.

Performance requirements in the electrical specifications are valid over an ambient temperature range of +20° C to +30° C. The Performance Requirement tolerances listed in the Electrical Specification are doubled over the temperature range of 0° C to +50° C, unless otherwise specified. Test equipment used to verify Performance Requirements must be calibrated and working within the limits specified in the Service Manual Equipment Required List.

Reference Information. Information that ampli-

fies a performance requirement or is of special importance is indicated by RI. There is no need to check these items to a specific tolerance.

ReliabilityMean Time Between Failure (MTBF)

The demonstrated MTBF goal is 40637 hours MTBF at 25° C ambient, which will be monitored from field failure reports.

Mean Time to Repair (MTTR)The projected MTTR is 1 hour.

1740A/1750A Series Waveform/Vector Monitor User Manual

A-1