At A Glance

REF

HEXT toggles between external reference (EXT LED on) and internal reference. Internal reference can be configured for component operation, and two external reference inputs can be designated for dual-standard instruments. See the CONFIGURE men on page 3-18.

INPUT

HSelecting a front-panel input causes the signal that is input to the corresponding rear-panel connector to be displayed on screen.

HWithout PARADE or OVERLAY selected, only one input selection can be made at a time. Each input channel button (including A123 / B123) toggles between A and B, and is cancelled when another input button is pressed.

HWith PARADE or OVERLAY selected, multiple input selections can be made; input buttons select A, B, both, or off, and do not cancel each other.

A123

A123 provides a side-by-side display of the CH-A1,CH-A2,and CH-A3inputs (B123 displays the CH-B1,CH-B2,and CH-B3inputs). Selecting A123or B123 turns off all other input channels. When PARADE or OVERLAY is selected, A123 and B123 can be displayed together and in combination with other inputs.

PARADE

PARADE displays up to four input channels side-by- side, with any additional inputs overlaid. Selecting PARADE displays the input channel(s) last selected for PARADE, allowing a custom configuration of inputs. In PARADE mode, the LINE/FIELD button offers only two choices: one line and one field.

2-6

1740A/1750A Series Waveform/Vector Monitor User Manual