Step 2. Connect Phonecell SX4D to AC Power

1)Connect the DC barrel connector of the 6 VDC Power Supply to the rear panel receptacle of the Phonecell SX4D - see Figure 3.

WARNING!

Never operate your Phonecell ! SX4D when any person is within

1 inch (2,5 cm) of the antenna.

DC

Receptacle

2)Plug the 6 VDC power supply into the AC socket - see Figure 4.

Wait for the unit to acquire service - see the

Phonecell SX4D Operation section of this manual.

Emergency Battery Backup

The Phonecell SX4D can accommodate six (6) standard AAA alkaline batteries (not supplied) for operation when AC power is not available. To install batteries, set the unit upside down, remove the screw to the battery access door, press the battery access door tab and remove the battery access door. Install the batteries and reinstall the battery access door - see Figure 9.

A switch is used to select either AC or internal battery operation - see Figure 17. When the battery operation is selected, the Phonecell SX4D will operate for approximately 10 minutes of talk time with fresh batteries.

NOTE: The Phonecell SX4D does not support rechargeable AAA batteries.

Figure 3 – Wall 6 VDC, 3-wire power supply DC connection.

AC

Power

Figure 4 – 6 VDC power supply connection to AC power.

SX4D GSM 900 • SX4D GSM 1800