Phonecell SX4D Programming - continued

IMPORTANT!

The following commands may be used by a trained service technician to change the configuration of the Phonecell SX4D. WARNING: these commands are

!intended for use by trained service technicians only. Untrained users could damage the Phonecell SX4D, violate local regulations and breach the service agreement with the cellular provider. For further assistance, please contact your Authorized Telular Representative.

Phonecell SX4D Technician Commands

The following commands are to used by trained field technicians to set up the Phonecell SX4D for operation in the network. Since these commands can directly affect the proper operation of the unit, there is an additional level of security to prevent casual access.

While in the User Programming mode, the technician presses the flash and redial keys simultaneously. A "PASSWORD" label will be displayed on the alpha row. The technician enters the password. As the password digits are entered from the keypad, only the center segment of the dialed digits row will illuminate. Note that as an exception to entry rule #4, the NEW icon will not illuminate, since the pass- word data is not being changed. When the technician presses the Redial key, the password is processed. If the password is correct, the "DTRCT" label is displayed on the alpha row. If not, the incorrect entry rule #7 will be followed, except that the NEW icon will not be illuminated. If the user fails to enter the correct password after three tries, the programming mode is exited without flashing the dialed digit row.

The following commands are displayed when the technician enters the program- ming mode. In the following sections, an <entered value> is comprised of the dig- its 0 through 9.

Enter Dial Tone After Remote Call Terminate Option

The following key sequence is used to enter the dial tone after remote call terminate option:

Label: DTRCT

Data: <dial tone option>

The dial tone value is set to 0 for no tone after a remote on-hook; 1 to enable dial tone after remote on hook. If the value is neither 0 nor 1, it is considered invalid. The factory default is 1.

Enter Post Receiver Off-Hook Option

The following key sequence is used to enter the post receiver off-hook option:

Label: POST ROH

Data: <post ROH option>

The post ROH value is set to 0 for continuous ROH tone; 1 to disable ROH tone and periodically check for an on-hook condition. If the post ROH value is neither 0 nor 1, it is considered invalid. The factory default is 1.

SX4D GSM 900 • SX4D GSM 1800