Schneider Electric 61 user manual Not separate mode, Separate mode, 10V +10V, Terminals, CANopen

Models: 61

1 131
Download 131 pages 6.3 Kb
Page 35
Image 35
Not separate mode

Command/reference switching

Not separate mode

Command and reference come from the same channel.

-10V

+10V

-10VTERMINALS

TERMINALSSeparate modeCANopenCommand ReferenceDigital

In CiA402 profile, the not separate mode is configured via the terminal:

Menu

Parameter

Value

 

 

 

[1.6 - COMMAND] (CtL-)

[Profile] (CHCF)

[Not separ.] (SIM)

 

 

 

Separate mode

Command and reference may come from different channels.

CANopen

Digital

reference

Manual backgroundTERMINALS CANopen

Manual backgroundManual backgroundManual backgroundCommand ReferenceManual background

In CiA402 profile, the separate mode is achieved via configuration with the terminal:

Menu

Parameter

Value

 

 

 

[1.6 - COMMAND] (CtL-)

[Profile] (CHCF)

[Separate] (SEP)

 

 

 

In I/O profile, the drive is automatically in separate mode.

 

 

 

 

Menu

Parameter

Value

 

 

 

[1.6 - COMMAND] (CtL-)

[Profile] (CHCF)

[I/O profile] (IO)

 

 

 

35

Page 35
Image 35
Schneider Electric 61 user manual Not separate mode, Separate mode, 10V +10V, Terminals, CANopen, Digital reference