Identification parameters

Identification parameters

Code

 

 

 

Description

 

 

 

 

 

 

 

 

nCVr

Parameter name:

Drive nominal rating

 

 

 

 

 

 

 

 

 

 

 

Logic address:

3020 = 16#0BCC

 

Type:

WORD (listing)

 

CANopen index:

2000/15

 

Read/write:

R

 

INTERBUS index:

5FB0/0A

 

Unit:

-

 

DeviceNet path:

70/01/15

 

 

 

 

 

 

 

 

 

 

 

 

0 = nO (Unknown rating)

 

25

= D55 (55 kW / 75 HP)

 

 

 

 

 

26

= D75 (75 kW / 100 HP)

 

 

4 = 037 (0.37 kW / 0.5 HP)

 

27

= D90 (90 kW / 125 HP)

 

 

 

 

 

28

= C11 (110 kW / 150 HP)

 

 

6 = 075 (0.75 kW / 1 HP)

 

29

= C13 (132 kW / 200 HP)

 

 

 

 

 

30

= C16 (160 kW / 250 HP)

 

 

9 = U15 (1.5 kW / 2 HP)

 

31

= C20 (200 kW / 300 HP)

 

 

 

 

 

32

= C22 (220 kW / 350 HP)

 

 

11

= U22 (2.2 kW / 3 HP)

 

33

= C25 (250 kW / 400 HP)

 

 

12

= U30 (3 kW)

 

34

= C28 (280 kW / 450 HP)

 

 

14

= U40 (4 kW / 5 HP)

 

35

= C31 (315 kW / 500 HP)

 

 

 

 

 

 

 

 

15

= U55 (5.5 kW / 7.5 HP)

 

37

= C40 (400 kW / 600 HP)

 

 

16

= U75 (7.5 kW / 10 HP)

 

39

= C50 (500 kW / 700 HP)

 

 

 

 

 

 

 

18

= D11 (11 kW / 15 HP)

 

40

= C56 (560 kW)

 

 

19

= D15 (15 kW / 20 HP)

 

41

= C63 (630 kW)

 

 

20

= D18 (18.5 kW / 25 HP)

 

42

= C71 (710 kW)

 

 

21

= D22 (22 kW / 30 HP)

 

43

= C80 (800 kW)

 

 

22

= D30 (30 kW / 40 HP)

 

44

= C90 (900 kW)

 

 

23

= D37 (37 kW / 50 HP)

 

45

= M12 (1200 kW)

 

 

24

= D45 (45 kW / 60 HP)

 

 

 

 

 

 

 

 

 

 

 

 

UCAL

Parameter name:

Drive voltage

 

 

 

 

 

 

 

 

 

 

 

Logic address:

3012 = 16#0BC4

 

Type:

WORD (listing)

 

CANopen index:

2000/D

 

Read/write:

R

 

INTERBUS index:

5FB0/03

 

Unit:

-

 

DeviceNet path:

70/01/0D

 

 

 

 

 

 

 

 

 

 

 

 

3 = 220 V single-phase (M2)

 

 

 

 

 

 

4 = 220 V three-phase (M3)

 

 

 

 

 

 

6 = 480 V three-phase (N4)

 

 

 

 

 

 

8 = 690 V three-phase (S6)

 

 

 

 

 

 

 

 

 

 

 

 

InV

Parameter name:

Rated drive current

 

 

 

 

 

 

 

 

 

 

 

Logic address:

3017 = 16#0BC9

 

Type:

UINT

 

CANopen index:

2000/12

 

Read/write:

R

 

INTERBUS index:

5FB0/07

 

Unit:

0.1 A

 

DeviceNet path:

70/01/12

 

 

 

 

 

 

 

 

 

 

UdP

Parameter name:

Drive software version

 

 

 

 

 

 

 

 

 

Logic address:

3302 = 16#0CE6

 

Type:

UINT

 

CANopen index:

2003/3

 

Read/write:

R

 

INTERBUS index:

5FB0/0F

 

Unit:

1

 

DeviceNet path:

71/01/67

 

 

 

 

 

 

 

 

 

 

 

 