Schneider Electric 61 ODVA standard configuration and adjustment parameters, Code, Description

Models: 61

1 131
Download 131 pages 6.3 Kb
Page 122
Image 122
ODVA standard configuration and adjustment parameters

ODVA standard configuration and adjustment parameters

Code

 

Description

 

 

 

 

 

 

ACCd

Parameter name:

ODVA acceleration time

 

 

 

ODVA name:

AccelTime

 

 

 

 

 

 

 

 

Logic address:

-

Type:

UINT

 

CANopen index:

-

Read/write:

R/W

 

INTERBUS index:

-

Unit:

ms

 

DeviceNet path:

2A/01/12

 

 

 

 

 

 

 

 

Parameter conforming to ODVA profile.

 

 

 

Speed for calculation of acceleration ramp.

 

 

 

Writing this parameter also modifies:

 

 

 

[Acceleration] (ACC)

 

 

 

• CiA402 "vl velocity acceleration/delta speed" (SPAL) and "vl velocity acceleration/delta time" (SPAt)

 

Parameter only accessible via DeviceNet.

 

 

 

 

 

 

 

dECd

Parameter name:

ODVA deceleration time

 

 

 

ODVA name:

DecelTime

 

 

 

 

 

 

 

 

Logic address:

-

Type:

UINT

 

CANopen index:

-

Read/write:

R/W

 

INTERBUS index:

-

Unit:

ms

 

DeviceNet path:

2A/01/13

 

 

 

 

 

 

 

 

Parameter conforming to ODVA profile.

 

 

 

Speed for calculation of deceleration ramp.

 

 

 

Writing this parameter also modifies:

 

 

 

[Deceleration] (dEC)

 

 

 

• CiA402 "vl velocity deceleration/delta speed" (SPdL) and "vl velocity deceleration/delta time" (SPDt)

 

Parameter only accessible via DeviceNet.

 

 

 

 

 

 

 

LSPd

Parameter name:

ODVA low speed limit

 

 

 

ODVA name:

LowSpdLimit

 

 

 

 

 

 

 

 

Logic address:

-

Type:

UINT

 

CANopen index:

-

Read/write:

R/W

 

INTERBUS index:

-

Unit:

rpm

 

DeviceNet path:

2A/01/14

 

 

 

 

 

 

 

 

Parameter conforming to ODVA profile

 

 

 

Parameter only accessible via DeviceNet.

 

 

 

 

 

 

 

HSPd

Parameter name:

ODVA high speed limit

 

 

 

ODVA name:

HighSpdLimit

 

 

 

 

 

 

 

 

Logic address:

-

Type:

UINT

 

CANopen index:

-

Read/write:

R/W

 

INTERBUS index:

-

Unit:

rpm

 

DeviceNet path:

2A/01/15

 

 

 

 

 

 

 

Parameter conforming to ODVA profile

Parameter only accessible via DeviceNet.

122

Page 122
Image 122
Schneider Electric 61 ODVA standard configuration and adjustment parameters, Code, Description, ODVA acceleration time