Configuration saving and switching

Function parameters

Code

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

CNF1

Parameter name:

Assignment for 2 configurations

 

 

 

 

Terminal display:

[2 Configurations]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Logic address:

8021 = 16#1F55

 

Type:

WORD (listing)

 

 

CANopen index:

2032/16

 

Read/write:

R/WS

 

 

 

INTERBUS index:

5FBC/9C

 

Factory setting:

0

 

 

 

DeviceNet path:

9C/01/9C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See next page.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNF2

Parameter name:

Assignment for 3 configurations

 

 

 

 

Terminal display:

[3 Configurations]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Logic address:

8022 = 16#1F56

 

Type:

WORD (listing)

 

 

CANopen index:

2032/17

 

Read/write:

R/WS

 

 

 

INTERBUS index:

5FBC/9D

 

Factory setting:

0

 

 

 

DeviceNet path:

9C/01/9D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See next page.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNFS

Parameter name:

Active configuration

 

 

 

 

 

 

 

 

Terminal display:

[Config. active]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Logic address:

8020 = 16#1F54

 

Type:

WORD (listing)

 

 

CANopen index:

2032/15

 

Read/write:

R

 

 

 

INTERBUS index:

5FB9/D1

 

 

 

 

 

 

 

 

DeviceNet path:

89/01/15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = The parameter set switching function is not configured

 

 

 

 

1 = (CNF0): Configuration no. 0 active

 

 

 

 

 

 

 

 

2 = (CNF1): Configuration no. 1 active

 

 

 

 

 

 

 

 

3 = (CNF2): Configuration no. 2 active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Value of the control bit assigned by [2 Configurations] (CnF1)

 

 

0

 

1

0

1

 

 

 

 

 

 

 

Value of the control bit assigned by [3 Configurations] (CnF2)

 

 

0

 

0

1

1

 

 

 

 

 

 

 

 

Value of [Config. active] (CnFS)

 

 

 

1

 

2

3

3

 

 

 

 

 

 

 

 

Active configuration

 

 

 

0

 

1

2

2

 

 

 

 

 

 

 

 

 

 

63

Page 63
Image 63
Schneider Electric 61 user manual Function parameters, CNF1, CNF2, Cnfs