Output value parameters

Output value parameters

Output values (speed)

Code

 

 

Description

 

 

 

 

 

 

 

rFrd

Parameter name:

Output speed

 

 

 

 

CiA402 name:

vl control effort

 

 

 

 

DRIVECOM name:

Speed-Actual-Value

 

 

 

 

 

 

 

 

 

 

Logic address:

8604 = 16#219C

 

Type:

INT

 

CANopen index:

6044/0

 

Read/write:

R

 

INTERBUS index:

6044/0

 

Unit:

rpm

 

DeviceNet path:

2A/01/07 (1)

 

 

 

 

 

8C/01/05 (2)

 

 

 

 

 

 

 

 

 

Parameter conforming to CiA402 and ODVA profiles

 

 

Signed value.

 

 

 

 

 

If the drive is in open-loop mode, the speed value is estimated.

 

 

If the drive is in closed-loop mode, the speed value is measured on the sensor.

 

 

This parameter is linked to the "Output frequency" (rFr) parameter for which the unit is 0.1 Hz.

 

 

 

 

 

 

rFr

Parameter name:

Output frequency

 

 

 

 

Terminal display:

[Output frequency]

 

 

 

 

 

 

 

 

 

 

Logic address:

3202 = 16#C82

 

Type:

INT

 

CANopen index:

2002/3

 

Read/write:

R

 

INTERBUS index:

5FB9/04

 

Unit:

0.1 Hz or standardized 16

 

DeviceNet path:

71/01/03

 

 

signed bits based on the

 

 

 

maximum frequency (TFR)

 

 

 

 

 

 

 

 

 

 

 

 

Signed value.

 

 

 

 

The unit depends on the value of bit 9 of the extended control word:

=0: 0.1 Hz

=1: Standardized value on 16 signed bits at maximum frequency. The value 32767 corresponds to [Max frequency] (TFR). The default value of [Max frequency] (TFR) is 60 Hz, and the resolution is then approximately 0.0018 Hz.

(1)ODVA standard path. It can be used for explicit messaging. Do not use it for configuring an assembly.

(2)Altivar path. To ensure better interchangeability, avoid using it for explicit messaging. This is the path that must be used for configuring an assembly.