Output value parameters
Output values (speed)
Code |
|
| Description |
| |
|
|
|
|
|
|
rFrd | Parameter name: | Output speed |
|
|
|
| CiA402 name: | vl control effort |
|
|
|
| DRIVECOM name: |
|
|
| |
|
|
|
|
|
|
| Logic address: | 8604 = 16#219C |
| Type: | INT |
| CANopen index: | 6044/0 |
| Read/write: | R |
| INTERBUS index: | 6044/0 |
| Unit: | rpm |
| DeviceNet path: | 2A/01/07 (1) |
|
|
|
|
| 8C/01/05 (2) |
|
|
|
|
|
|
|
| |
| Parameter conforming to CiA402 and ODVA profiles |
| |||
| Signed value. |
|
|
|
|
| If the drive is in |
| |||
| If the drive is in |
| |||
| This parameter is linked to the "Output frequency" (rFr) parameter for which the unit is 0.1 Hz. | ||||
|
|
|
|
|
|
rFr | Parameter name: | Output frequency |
|
|
|
| Terminal display: | [Output frequency] |
|
|
|
|
|
|
|
|
|
| Logic address: | 3202 = 16#C82 |
| Type: | INT |
| CANopen index: | 2002/3 |
| Read/write: | R |
| INTERBUS index: | 5FB9/04 |
| Unit: | 0.1 Hz or standardized 16 |
| DeviceNet path: | 71/01/03 |
|
| signed bits based on the |
|
|
| maximum frequency (TFR) | ||
|
|
|
|
| |
|
|
|
|
|
|
| Signed value. |
|
|
|
|
The unit depends on the value of bit 9 of the extended control word:
=0: 0.1 Hz
=1: Standardized value on 16 signed bits at maximum frequency. The value 32767 corresponds to [Max frequency] (TFR). The default value of [Max frequency] (TFR) is 60 Hz, and the resolution is then approximately 0.0018 Hz.
(1)ODVA standard path. It can be used for explicit messaging. Do not use it for configuring an assembly.
(2)Altivar path. To ensure better interchangeability, avoid using it for explicit messaging. This is the path that must be used for configuring an assembly.
87