Command/reference switching

Copy on switching

When switching channels, it is possible to copy the reference or command from function channel 1 to direct channel 2.

Menu

 

Submenu

 

 

 

[1.6 COMMAND] (CtL-)

 

 

 

 

 

 

 

Parameter

Possible values

 

 

[Copy channel 1 --> 2]

No copy.

 

[No] (nO)

 

Copy reference

 

[Reference] (SP)

 

Copy command

 

[Command] (Cd)

 

Copy command and reference

 

[Cmd + ref.] (ALL)

 

 

 

If a copy is not made, the drive stops according to the configured stop type [Type of stop] (Stt) until the first command and reference are received.

The reference before ramp (FrH) is copied unless the direct channel 2 reference is via +/- speed.

If the direct channel 2 reference is via +/- speed, the after ramp (rFr) reference is copied.

If the direct channel 2 command is via the terminals, the function channel 1 command is not copied even in pulse control (3-wire) [3 wire] (3C).

If the direct channel 2 reference is via AI1, AI2, AI3, AI4, the encoder input or frequency input, the function channel 1 reference is not copied.