Log parameters

Log of the following faults

The log shown for the first fault can be used to review the last 8 faults. All codes and addresses are summarized in the tables below.

Fault n-1

Log

Code

Logic address:

CANopen

INTERBUS

DeviceNet

 

 

 

index:

index:

path:

 

 

 

 

 

 

Fault code

dP1

7201 = 16#1C21

202A/2

5FB9/5A

85/01/02

 

 

 

 

 

 

Power supply voltage

ULP1

7271 = 16#1C67

202A/48

5FB9/99

85/01/48

 

 

 

 

 

 

Motor current

LCP1

7241 = 16#1C49

202A/2A

5FB9/7E

85/01/2A

 

 

 

 

 

 

Output frequency

rFP1

7251 = 16#1C53

202A/34

5FB9/87

85/01/34

 

 

 

 

 

 

Motor thermal state

tHP1

7281 = 16#1C71

202A/52

5FB9/A2

85/01/52

 

 

 

 

 

 

Status word

EP1

7211 = 16#1C2B

202A/C

5FB9/63

85/01/0C

 

 

 

 

 

 

Extended status word

IP1

7221 = 16#1C35

202A/16

5FB9/6C

85/01/16

 

 

 

 

 

 

Command word

CMP1

7231 = 16#1C3F

202A/20

5FB9/75

85/01/20

 

 

 

 

 

 

Active command channel

dCC1

64301 = 16#FB2D

 

5FBA/22

 

 

 

 

 

 

 

Active reference channel

drC1

64311 = 16#FB37

 

5FBA/2B

 

 

 

 

 

 

 

Active channels

CrP1

7291 = 16#1C7B

202A/5C

5FB9/AB

85/01/5C

 

 

 

 

 

 

Motor operating time

rtP1

7261 = 16#1C5D

202A/3E

5FB9/90

85/01/3E

 

 

 

 

 

 

Date

Md1

7301 = 16#1C85

202B/2

5FB9/B4

85/01/66

 

 

 

 

 

 

Time

dM1

7311 = 16#1C8F

202B/C

5FB9/BD

85/01/70

 

 

 

 

 

 

Fault n-2

 

 

 

 

 

 

 

 

 

 

 

Log

Code

Logic address:

CANopen

INTERBUS

DeviceNet

 

 

 

index:

index:

path:

 

 

 

 

 

 

Fault code

dP2

7202 = 16#1C22

202A/3

5FB9/5B

85/01/03

 

 

 

 

 

 

Power supply voltage

ULP2

7272 = 16#1C68

202A/49

5FB9/9A

85/01/49

 

 

 

 

 

 

Motor current

LCP2

7242 = 16#1C4A

202A/2B

5FB9/7F

85/01/2B

 

 

 

 

 

 

Output frequency

rFP2

7252 = 16#1C54

202A/35

5FB9/88

85/01/35

 

 

 

 

 

 

Motor thermal state

tHP2

7282 = 16#1C72

202A/53

5FB9/A3

85/01/53

 

 

 

 

 

 

Status word

EP2

7212 = 16#1C2C

202A/D

5FB9/64

85/01/0D

 

 

 

 

 

 

Extended status word

IP2

7222 = 16#1C36

202A/17

5FB9/6D

85/01/17

 

 

 

 

 

 

Command word

CMP2

7232 = 16#1C40

202A/21

5FB9/76

85/01/21

 

 

 

 

 

 

Active command channel

dCC2

64302 = 16#FB2E

 

5FBA/23

 

 

 

 

 

 

 

Active reference channel

drC2

64312 = 16#FB38

 

5FBA/2C

 

 

 

 

 

 

 

Active channels

CrP2

7292 = 16#1C7C

202A/5D

5FB9/AC

85/01/5D

 

 

 

 

 

 

Motor operating time

rtP2

7262 = 16#1C5E

202A/3F

5FB9/91

85/01/3F

 

 

 

 

 

 

Date

Md2

7302 = 16#1C86

202B/3

5FB9/B5

85/01/67

 

 

 

 

 

 

Time

dM2

7312 = 16#1C90

202B/D

5FB9/BE

85/01/71

 

 

 

 

 

 

111