Schneider Electric 61 user manual Assignment of logic inputs and control bits for CNF1 and CNF2

Models: 61

1 131
Download 131 pages 6.3 Kb
Page 64
Image 64
Assignment of logic inputs and control bits for CNF1 and CNF2

Configuration saving and switching

Assignment of logic inputs and control bits for CNF1 and CNF2

Value

Assignment

Description/Condition

 

 

 

0

Not assigned

 

 

 

 

129

[LI1] (LI1)

Logic inputs

to

to

 

134

[LI6] (LI6)

Drive with or without option

 

 

 

135

[LI7] (LI7)

Logic inputs

to

to

 

138

[LI10] (LI10)

With VW3A3201 logic I/O card

 

 

 

139

[LI11] (LI11)

Logic inputs

to

to

 

142

[LI14] (LI14)

With VW3A3202 extended I/O card

 

 

 

187

[C111] (C111)

Control bit

to

to

 

191

[C115] (C115)

With integrated Modbus regardless of configuration

 

 

 

203

[C211] (C211)

Control bit

to

to

 

207

[C215] (C215)

With integrated CANopen regardless of configuration

 

 

 

219

[C311] (C311)

Control bit

to

to

 

223

[C315] (C315)

With a communication card regardless of configuration

 

 

 

235

[C411] (C411)

Control bit

to

to

 

239[C415] (C415) With Controller Inside card regardless of configuration

Note: In [I/O profile] (IO) configuration, LI1 cannot be accessed and if [2/3 wire control] (tCC) = [3 wire] (3C); LI2 cannot be accessed either.

64

Page 64
Image 64
Schneider Electric 61 Assignment of logic inputs and control bits for CNF1 and CNF2, Configuration saving and switching