Schneider Electric 61 CiA402 standard configuration and adjustment parameters, Description

Models: 61

1 131
Download 131 pages 6.3 Kb
Page 118
Image 118
CiA402 standard configuration and adjustment parameters

CiA402 standard configuration and adjustment parameters

Code

 

 

 

Description

 

 

 

 

 

 

 

SMIL

Parameter name:

Minimum speed

 

 

 

 

CiA402 name:

vl velocity min speed

 

 

 

 

DRIVECOM name:

Speed-Min-Amount

 

 

 

 

 

 

 

 

 

 

Logic address:

8607 = 16#219F

 

Type:

UDINT

 

 

 

and 8608 = 16#21A0

 

 

 

 

CANopen index:

6046/1

 

Read/write:

R/W

 

INTERBUS index:

6046/1

 

Unit:

rpm

 

DeviceNet path:

8C/01/08

 

 

 

 

 

 

 

 

 

 

Parameter conforming to CiA402 profile

 

 

 

 

32-bit word (low order: 8607, high order: 8608). High orders always = 0.

 

 

Writing this parameter also modifies:

 

 

 

 

[Low speed] (LSP)

 

 

 

 

 

ODVA low speed limit (LSPd)

 

 

 

 

 

 

 

 

 

SMAL

Parameter name:

Maximum speed

 

 

 

 

CiA402 name:

vl velocity max speed

 

 

 

 

DRIVECOM name:

Speed-Max-Amount

 

 

 

 

 

 

 

 

 

 

Logic address:

8609 = 16#21A1

 

Type:

UDINT

 

 

 

and 8610 = 16#21A2

 

 

 

 

CANopen index:

6046/2

 

Read/write:

R/W

 

INTERBUS index:

6046/2

 

Unit:

rpm

 

DeviceNet path:

8C/01/0A

 

 

 

 

 

 

 

 

 

 

Parameter conforming to CiA402 profile

 

 

 

 

32-bit word (low order: 8609, high order: 8610). High orders always = 0.

 

 

Writing this parameter also modifies:

 

 

 

 

[High speed] (HSP)

 

 

 

 

 

ODVA high speed limit (HSPd)

 

 

 

 

 

 

 

SPAL

Parameter name:

Acceleration speed delta

 

 

CiA402 name:

vl velocity acceleration/delta speed

 

 

DRIVECOM name:

Speed-Acceleration/Delta speed

 

 

 

 

 

 

 

 

Logic address:

8611 = 16#21A3

 

Type:

UDINT

 

 

 

and 8612 = 16#21A4

 

 

 

 

CANopen index:

6048/1

 

Read/write:

R/W

 

INTERBUS index:

6048/1

 

Unit:

rpm

 

DeviceNet path:

8C/01/0C

 

 

 

 

 

 

 

 

 

 

Parameter conforming to CiA402 profile Speed for calculation of acceleration ramp.

32-bit word (low order: 8611, high order: 8612).

If writing registers 8611 and 8612 in succession, write register 8611 first, then register 8612. Writing this parameter also modifies:

[Acceleration] (ACC)

ODVA acceleration time

118

Page 118
Image 118
Schneider Electric 61 CiA402 standard configuration and adjustment parameters, Description, Minimum speed, Maximum speed