8.Saving and Restoring Configuration Parameters

After the CMS-6R4 has been properly configured, parameters can be downloaded and saved as an ASCII text file on your local or remote PC. Later, if the configuration is accidentally altered, the file with the saved parameters can be uploaded to automatically reconfigure the unit without the need to manually assign each parameter.

Saved parameters can also be uploaded to other CMS-6R4 units. This allows rapid set-up when several units will be configured with the same parameters.

The "Save Parameters" procedure can be performed from any terminal emulation program (e.g. ProComm, Crosstalk, Hyperterminal, etc.), which allows downloading of ASCII files.

Notes:

Although this function is only available via the Text Interface, parameters that are defined via the Web Browser Interface will also be sent to the ASCII file.

Note that the "Save Parameters" feature is only available when the Supervisor Mode is active.

8.1.Sending Parameters to a File

1.Start your communications program and access the CMS-6R4 command mode using a Password and port that permit access to Supervisor Level commands.

2.When the CMS-6R4 command prompt appears, type /U and press [Enter]. The CMS-6R4 will prompt you to prepare your communications program. Set up your communications program to receive an ASCII download, and specify a name for the file that will receive the saved parameters (e.g. CMS6R4.PAR).

3.When the communications program is ready to receive the file, return to the CMS-6R4 command mode, and press [Enter] to proceed.

4.The CMS-6R4 will send a series of ASCII command lines which specify the currently selected parameters.

8-1

Page 95
Image 95
I-Tech Company CMS 6R4 Series manual Saving and Restoring Configuration Parameters, Sending Parameters to a File