CMS-6R4 Series - User’s Guide
COPY SERIAL PORT PARAMETERS: |
| |
1. | Port Name: | 15. Direct Connect: |
2. | Baud Rate: |
|
3. | Bits/Parity: |
|
4. | Stop Bits: |
|
5. | Handshake Mode: |
|
6. | Port Mode: |
|
7. | 64. DTR Output: |
|
Supervisor Mode: |
| |
8. | Logoff Character: |
|
9. | Sequence Disconnect: |
|
10. | Inactivity Timeout: |
|
11. | Response Type: |
|
12. | Command Echo: |
|
13. | Accept Break: |
|
14. | Invalid Access Lockout: |
|
(Note: Port 1 will NOT have restricted values changed.)
Enter: Parameter # <CR> to define parameter value(s) to copy to other ports,
X<CR> to exit WITHOUT copy,
<ESC> to copy to ports and exit ...
Figure 5.16: The Copy Parameters Menu - Text Interface
5.5.3.2. Copying Parameters to Several Ports
The /CP command (Copy Port Parameters) provides a convenient means for selecting similar parameters for all or several
When the /CP command is invoked, the unit will display a menu which allows you to select parameters, and then copy them to all or several Serial Ports. The Copy Port Parameters menu can be used to set all parameters for the specified port(s), or define only a select group of parameters for the desired ports.
Notes:
•The /CP command will not copy parameters to the Network Port.
•The /CP command can only be invoked via the Text Interface.
•The /CP command is only available to passwords and ports that permit access to Supervisor Level commands.
•The /CP command cannot be used to set Port 1 (the System Setup Port) to Passive Mode or Buffer Mode.
•The /CP command cannot be used to disable the Supervisor Mode at Port 1 (the System Setup Port.)
To select common parameters for all or several
1.Access the Command Mode via the Text Interface, using a password and port that permit access to Supervisor Level commands.