CMS-6R4 Series - User’s Guide
/CP | Copy RS232 Port Parameters |
Allows quick
Availability: Supervisor Only
Format: /CP <x> [Enter]
Where:
xIs the number of the port(s) where the copied parameters will be applied. To apply the command to several ports, enter a comma between each port number. To apply the command to a range of ports, enter the numbers for the first and last ports in the range, separated by a dash character
Response: Displays Copy Parameters Menu.
/D | Third Party Disconnect |
Invoke the /D command at your resident port to disconnect two other ports. Note that the /D command cannot disconnect your resident port.
Availability: Supervisor Only
Format: /D[,Y] <x> [x] [Enter]
Where: |
|
,Y | (Optional) suppresses the "Sure?" prompt. |
x | Is the number or name of the port(s) to be disconnected. To |
| apply the command to several plugs, enter a space character or |
| a plus sign (+) between each plug number. To apply the |
| command to a range of plugs, enter the numbers for the first |
| and last plugs in the range, separated by a colon character (:). |
| To apply the command to all plugs allowed by your password, |
| enter an asterisk character (*). |
Response:
Verbose: "Sure (y/n)?", if Y, unit will respond with "Disconnected".
Terse: 5, if Y, unit will respond with 3.
Example: To disconnect Port 2 from Port 3 without the "Sure?" prompt, access the Command Mode from a third port with Supervisor Level command capability and type:
/D,Y 2 [Enter] or /D,Y 3 [Enter]