The Speaker Company ta200 manual 4.3.2 Gap/Black Mark Calibration, Self-test and Dump Mode

Models: ta200

1 49
Download 49 pages 35.84 Kb
Page 30
Image 30

The LED color will be changed as following order

Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks) red/amber (5 blinks) solid green

Note:

Please select gap or black mark sensor by sending GAP or BLINE command to printer prior to

calibrate the sensor.

For more information about GAP and BLINE command, please refer to TSPL2 programming

manual.

4.3.2 Gap/Black Mark Calibration, Self-test and Dump Mode

While calibrate the gap/black mark sensor, printer will measure the label length, print the internal configuration (self-test) on label and then enter the dump mode. To calibrate gap or black mark sensor, depends on the sensor setting in the last print job.

Please follow the steps below to calibrate the sensor.

1.Turn off the power switch.

2.Hold on the button then turn on the power switch.

3.Release the button when LED becomes amber and blinking. (Any amber will do during the 5 blinks)

The LED color will be changed as following order.

Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks) red/amber (5 blinks) solid green

4.It calibrates the sensor and measures the label length and prints internal settings then enter the dump mode.

Note:

Please select gap or black mark sensor by Diagnostic Tool or by GAP or BLINE command prior to

calibrate the sensor.

For more information about GAP and BLINE command, please refer to TSPL2 programming

manual.

18

Page 30
Image 30
The Speaker Company ta200 manual 4.3.2 Gap/Black Mark Calibration, Self-test and Dump Mode