The Speaker Company ta200 Set Gap Sensor as Media Sensor and Calibrate the Gap Sensor, Parameter

Models: ta200

1 49
Download 49 pages 35.84 Kb
Page 34
Image 34

Printer configuration will be restored to defaults as below after initialization.

Parameter

Default setting

Speed

101.6 mm/sec (4 ips) (203DPI)

 

76 mm/sec (3 ips) (300DPI)

 

 

Density

8

 

 

Label Width

4” (101.5 mm)

 

 

Label Height

4” (101.5 mm)

 

 

Sensor Type

Gap sensor

 

 

Gap Setting

0.12” (3.0 mm)

 

 

Print Direction

0

 

 

Reference Point

0,0 (upper left corner)

 

 

Offset

0

 

 

Tear Mode

On

 

 

Peel off Mode

Off

 

 

Cutter Mode

Off

 

 

Serial Port Settings

9600 bps, none parity, 8 data bits, 1 stop bit

 

 

Code Page

850

 

 

Country Code

001

 

 

Clear Flash Memory

No

 

 

IP Address

DHCP

 

 

4.3.4 Set Black Mark Sensor as Media Sensor and Calibrate the Black Mark Sensor

Please follow the steps as below.

1.Turn off the power switch.

2.Hold on the button then turn on the power switch.

3.Release the button when LED turns green/amber after 5 green blinks. (Any green/amber will do during the 5 blinks).

The LED color will be changed as following:

Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks) red/amber (5 blinks) solid green

4.3.5Set Gap Sensor as Media Sensor and Calibrate the Gap Sensor

Please follow the steps as below.

1.Turn off the power switch.

2.Hold on the button then turn on the power switch.

22