Therma-Tru Hinged Patio Door System Single Panel Assembly Unit manual Install Strikes

Models: Hinged Patio Door System Single Panel Assembly Unit

1 16
Download 16 pages 37.67 Kb
Page 7
Image 7
INSTALL STRIKES

5

INSTALL STRIKES

Standard Strike Option - Inswing

NOTE:

Outswing units will have strike installed during unit installation.

Slide Strike Assembly onto Lock Jamb

Lightly bend tongue area of backing plate inward to allow for a snug fit then slide over edge of lock jamb into mortise.

Adjustable

security

backing

plate

Lock

jamb

(2) #9 x 3/4” flat

head screws

or

(2) 16 gauge

1/2” x 7/16”

crown staples

Fasten Security Strike Assembly to Lock Jamb

Fasten with (2) #9 x 3/4" flat head screws or (2) 16 gauge 1/2" x 7/16" crown staples (not supplied) through strike plate on back side of jamb.

NOTE:

Do not staple through screw holes when using staples in place of screws.

Multi-point Lock Option

Fasten Strike Plates to Lock Jamb

Fit strike plates into mortises on lock jamb. Pre-drill 3/32” dia. pilot holes through jamb. Fasten with (7) #8 x 5/8” flat head screws.

CAUTION:

Do not over torque screws.

(7) #8 x 5/8”

flat head

screws

#8 x 5/8”

6

Page 7
Image 7
Therma-Tru Hinged Patio Door System Single Panel Assembly Unit manual Install Strikes, Standard Strike Option - Inswing