Therma-Tru Fiber-Classic manual Prep Door For Foot Bolt, Attach Foot Bolt, 25INSTALL SILL CAP TOP

Models: Fiber-Classic Smooth-Star

1 24
Download 24 pages 62.98 Kb
Page 15
Image 15
PREP DOOR FOR FOOT BOLT

23

PREP DOOR FOR FOOT BOLT

Tear out template on page 16 to locate and drill holes for foot bolt.

Locate template on interior side of active panel towards inactive panel side. Align line on template with edge of active door panel and tape into place. Drill 1/8" dia. x 1" deep holes at hole locations shown on template. Remove template.

24

ATTACH FOOT BOLT

Align foot bolt to pre-drilled holes in active slab and fasten with the supplied S.S. pan head sheet metal screws included with the foot bolt

(3) #8 x 9/16" S.S. Pan Head

Sheet Metal Screws

(1)#8 x 1 ½" S.S. Pan Head Sheet Metal Screw

Locate on bottom right corner of the foot bolt.

25 INSTALL SILL CAP TOP

Place a continuous bead of clear sealant, to locations shown, along entire length of sill cap base.

Install sill cap top by starting at each jamb and working towards the center of the door. Use a rubber mallet to snap into place.

ATTACH FOOT BOLTSill cap top

(3) #8 x 9/16" S.S. Pan Head(1)#8 x 1 ½" S.S. Pan Head Sheet Metal ScrewSealant

Locate on bottom right corner of the foot bolt.Sill cap base

14

Page 15
Image 15
Therma-Tru Fiber-Classic, Smooth-Star manual Prep Door For Foot Bolt, Attach Foot Bolt, 25INSTALL SILL CAP TOP