E.Fuse blown at disconnect when primary power is connected

1.Voltage selection busbars connected incorrectly

a.Check and correct if necessary.

2.One leg of three-phase primary connected to chassis ground

a.Rewire input cable per Operating Manual.

3.Main transformer shorted

a.Replace main transformer

F.Fuse blown at disconnect when main contactor (W1 or W2) closes

1.Shorted input diode (D1-D6)

a.Refer to Section 4.05-E, Diode Check. Replace diode(s) as required.

2.Switching transistor (Q1) shorted to heatsink

a.Replace Q1, check heat-sink for possible dam- age. Refer to Section 4.05-M, Switching Con- trol Check (Q1).

3.Shorted input capacitor (C7-C12)

a.Replace capacitor if necessary

4.Shorted diode (D11-D14)

a.Check for proper 3-phase power at input termi- nal board, check diodes. Refer to Section 4.05- E, Diode Check.

5.Faulty Voltage Selection PC Board

a.If W1 and W2 come on simultaneously replace Voltage Selection PC Board.

6.Faulty main contactor (W1 or W2)

a.Check both contactors for welded contacts and replace contactor(s) if necessary

G.TEMP indicator on (red)

1.Unit overheated

a.Clean radiator and check for obstruction.

b.Excessive piloting; allow unit to cool

2.Faulty thermal sensor (TS1, TS2, or TS3)

a.Refer to Section 4.05-F, Thermal Sensing Circuit Circuit Check. Replace sensor(s) if necessary

3.Faulty Logic PC Board

a.Refer to Section 4.05-F, Thermal Sensing Circuit Check. Replace Logic PC Board if necessary

4.Faulty LED/Current Control PC Board

a.Refer to Section 4.05-F, Thermal Sensing Circuit Check. Replace LED/Current Control PC Board if necessary.

H.No GAS indicator; Motor and Pump operating; Other LED indicators normal; Both gases flow

1.Front panel RUN/SET/PURGE switch set to PURGE, or PURGE selected at Remote Control

a.Normal operation (purges plasma line only, sec- ondary pressure switch is not satisfied)

2.Gas pressure set too low

a.Adjust pressure

3.Faulty pressure switch (PS1 or PS2)

a.Jump switches one at a time and check for indi- cator to determine which has failed. Replace switch if necessary.

4.Faulty Logic PC Board

a.Refer to Section 4.05-G, Pressure Sensing Cir- cuit. Replace Logic PC Board if necessary

5.Faulty LED/Current Control PC Board

a.Refer to Section 4.05-G, Pressure Sensing Cir- cuit. Replace LED/Current Control PC Board if necessary.

6.Faulty SW3-B (secondary mode set to O2 or H2O )

a.With secondary mode set to O2 or H2O, check for continuity from wire #52 to #55 on SW3-B. If open, replace SW3-B.

7.If using Gas Control Option (GC3000) set for Water Secondary, faulty SW2-C in Gas Control.

a.With Merlin front panel secondary mode set to GAS and the Gas Control (GC3000) set to WATER, there should be continuity from wires #52 to #55. If not, SW2-C or connections to it are faulty.

I.GAS indicator off, plasma and/or secondary gas does not flow

1.Front panel RUN/SET/PURGE switch set to PURGE, or PURGE selected at Remote Control.

a.Normal operation (purges plasma line only, sec- ondary does not flow)

2.Secondary mode set to O2

a.No secondary flow is normal operation in O2 mode (but GAS indicator should be ON). Re- fer to symptom 'H' above.

SERVICE TROUBLESHOOTING

20

Manual 0-2533

Page 24
Image 24
Thermal Comfort 3000 manual Fuse blown at disconnect when primary power is connected, Temp indicator on red

3000 specifications

Thermal Comfort 3000 is an innovative solution designed to enhance indoor climate by ensuring optimal thermal comfort for users. As the demand for energy efficiency and sustainable building practices grows, Thermal Comfort 3000 emerges as a key player in providing customizable and effective climate control systems.

One of the main features of Thermal Comfort 3000 is its advanced smart technology that allows for precise temperature regulation based on real-time data. It utilizes sensors that monitor indoor and outdoor temperatures, humidity levels, and even occupancy patterns. This data is then analyzed to optimize the heating and cooling systems, ensuring that energy is used efficiently. With its ability to automatically adjust to changing conditions, users can enjoy a consistent and comfortable environment without excessive energy consumption.

Thermal Comfort 3000 is built with user convenience in mind. It comes equipped with a user-friendly interface that enables easy adjustments and programming. Through a dedicated mobile app, users can control their indoor climate remotely, providing flexibility for those with busy lifestyles. Furthermore, the system offers customizable settings that cater to individual preferences, ensuring that everyone in a space can enjoy their ideal thermal environment.

The technology behind Thermal Comfort 3000 incorporates sustainable practices, utilizing eco-friendly refrigerants and energy-efficient components. This not only reduces the carbon footprint of buildings but also lowers energy costs for users. The system can be integrated with renewable energy sources, such as solar panels, creating a truly sustainable heating and cooling solution.

Thermal Comfort 3000 also features advanced filtration systems that improve indoor air quality. By removing allergens, dust, and other pollutants from the air, it promotes a healthier living environment. This is especially beneficial for individuals with allergies or respiratory issues, making Thermal Comfort 3000 an excellent choice for homes and commercial spaces alike.

In summary, Thermal Comfort 3000 represents the future of climate control technology. Its combination of smart features, user-centric design, and sustainability makes it an ideal solution for enhancing thermal comfort in any indoor environment. With its innovative approach, it not only ensures comfort but also promotes energy efficiency and environmental responsibility, making it a worthwhile investment for modern living.