12. Gas |
|
|
| Instructions |
|
|
|
| |||
| Pressures | the manual valve turned off to prevent flow to the gas valve, connect a manom- | |||||||||
|
|
|
|
| 1) Locate the 1/8” output pressure tap on the first valve (See FIGURE 8). With | ||||||
| (cont’d) | eter to the 1/8" pipe outlet pressure tap in the valve. NOTE: A manometer (fluid- | |||||||||
Check Valve Outlet | filled gauge) is recommended rather than a spring type gauge due to the difficulty | ||||||||||
Pressure (can only | of maintaining calibration of a spring type gauge. |
|
| ||||||||
be done after heater | 2) Open the manual valve and operate the heater. Measure the outlet pressure of | ||||||||||
the gas valve. To measure | |||||||||||
is operating) | |||||||||||
NOTE: If operating at high | sure to reconnect wire after testing.) |
|
|
| |||||||
Normally when operating at sea level, adjustments should not be necessary to the | |||||||||||
altitude, outlet pressure | |||||||||||
factory setting(s). (For high altitude settings, see below.) If adjustment is neces- | |||||||||||
requires adjustment. Follow | |||||||||||
sary, remove the cap from the adjustment screw(s). Set pressure to correct | |||||||||||
instructions below. | |||||||||||
settings by turning the regulator screw IN (clockwise) to increase pressure. Turn | |||||||||||
|
|
|
|
| |||||||
NOTES: If installation is | regulator screw OUT (counterclockwise) to decrease pressure. |
| |||||||||
3) If installing a Model LDAP 800, repeat to verify outlet pressure on second valve. | |||||||||||
above 6000 ft (1830M), a | |||||||||||
If installing a Model LDAP 1200, repeat to verify outlet pressure check on | |||||||||||
high altitude pressure switch | |||||||||||
second and third valve. |
|
|
| ||||||||
is required on each heat |
|
|
| ||||||||
Derate by Valve Outlet Pressure Adjustment for High | |||||||||||
section (all sizes). See | |||||||||||
Paragraph 5. |
|
|
| Altitude Operation |
|
|
| ||||
The main combustion air | Instructions for HighAltitude Derate |
|
|
| |||||||
pressure switch (Sizes 800 | 1. Determine the required valve outlet pressure for the elevation where the heater | ||||||||||
and 1200 only) does not need | will be operating. If unsure of the elevation, contact the local gas supplier. | ||||||||||
to be changed for high | Valve Outlet Pressure Settings by Elevation |
|
| ||||||||
altitude installation. |
|
| |||||||||
| Manifold Pressure Settings by Altitude for the UNITED STATES |
| |||||||||
FIGURE 8 - Top View of | Altitude | Natural Gas (inches w.c.) | Propane Gas (inches w.c.) | ||||||||
|
| ||||||||||
Valves showing Outlet | Feet | Meters | |||||||||
Low Fire | Low Fire | ||||||||||
Pressure Tap and |
|
| |||||||||
3.5 | 2.0 | 10.0 | 5.6 | ||||||||
Adjustment Locations | 3.1 | 1.7 | 8.8 | 5.0 | |||||||
|
|
|
|
| 3.0 | 1.7 | 8.5 | 4.8 | |||
|
|
| |||||||||
|
|
| 2.8 | 1.6 | 8.1 | 4.6 | |||||
2.7 | 1.5 | 7.7 | 4.4 | ||||||||
| Output | 1/8” Output |
|
| |||||||
|
|
| 2.6 | 1.5 | 7.4 | 4.2 | |||||
| Adjustment | Pressure Tap |
|
| 2.5 | 1.4 | 7.1 | 4.0 | |||
| Screw |
|
|
| 2.4 | 1.3 | 6.7 | 3.8 | |||
|
|
| 2.4 | 1.3 | 6.7 | 3.6 | |||||
|
|
|
|
| |||||||
| Inlet |
|
|
|
|
|
|
| |||
|
|
|
|
| Manifold | Pressure Settings by Altitude for CANADA |
| ||||
| Pressure |
|
|
| Altitude | Natural Gas (inches w.c.) | Propane Gas (inches w.c.) | ||||
| Tap |
|
|
| Feet | Meters | |||||
|
|
|
| Low Fire | Low Fire | ||||||
|
|
|
|
|
|
| |||||
| Two |
|
| 3.5 | 2.0 | 10.0 | 5.6 | ||||
|
|
| 2.8 | 1.6 | 8.1 | 4.6 | |||||
| on Model LDAP 400 only) |
|
| ||||||||
|
|
| 2. Locate the 1/8” output pressure tap on the first valve (See FIGURE 8). Turn | ||||||||
| Adjust High | Adjust Low |
|
| |||||||
|
|
| the knob on the top of the valve to “OFF”. Connect a manometer to the 1/8" | ||||||||
| Pressure |
|
| ||||||||
| Pressure |
|
| pipe outlet pressure tap in the valve. Use a water column manometer that is | |||||||
| Output |
|
| ||||||||
| Output |
|
| readable to the nearest tenth of an inch. |
|
|
| ||||
|
|
|
|
|
|
| |||||
|
|
|
|
| 3. | ||||||
|
|
|
|
| valve to “ON”. Remove the cap from the pressure adjusting screw and adjust | ||||||
|
|
|
|
| the gas train pressure to the pressure selected from the table above. Adjust | ||||||
| Inlet |
|
|
| pressure by turning the regulator screw IN (clockwise) to increase pressure or | ||||||
|
|
|
| OUT (counterclockwise) to decrease pressure. |
|
| |||||
| Pressure |
|
|
|
|
| |||||
| 1/8” Output |
|
| ||||||||
| Tap |
|
| ||||||||
|
|
| valve and check the low fire pressure. Turn the regulator screw to adjust the low | ||||||||
|
| Pressure |
|
| |||||||
|
|
|
| fire outlet pressure to the “Low Fire” pressure selected from the table. Re- | |||||||
|
| Tap |
|
| |||||||
|
|
|
| connect the wire to the gas valve. |
|
|
| ||||
|
|
|
|
|
|
|
| ||||
| Form |
| 2), Page 12 |
|
|
|
|
|