Thomas & Betts LDAP 1200 warranty Heater Location, Mounting Height Heater Throw - All Models

Models: LDAP 1200

1 40
Download 40 pages 36.87 Kb
Page 7
Image 7
10.Heater Location

10.Heater Location

Use the clearances in Paragraph 8; the combustion air requirements in Paragraph 9; the mounting height requirements, throw information, sound data, and location rec- ommendations below; the weights in Paragraph 11; and the venting requirements in Paragraph 24 to determine where to suspend the heater.

Mounting Height

Heater Throw - All Models

CAUTION: Do not locate the heater where it may be exposed to water spray, rain, or dripping water.

Locate the heater so that it is a minimum of 15 feet (4.6M) above the floor and in compliance with the clearances in Paragraph 8.

WARNING: If touched, the vent pipe and internal heater surfaces that are accessible from outside the heater will cause burns. Suspend the heater a minimum of 15 feet (4.6M) above the floor.

FIGURE 3 - Model LDAP Air Throw (Heat Mode @ High Speed) - Applies to All Sizes

Mounting

30° Nozzle

60° Nozzle

Height

 

Standard Louvers

 

 

X

0

 

Standard

 

 

Y

 

 

Louvers

 

 

Z

 

 

 

 

 

30° Nozzle

X

 

 

Y

 

 

 

Z

 

 

60° Nozzle

X

 

 

Y

 

 

 

Z

0 = “Rear” of Heater Discharge

 

 

 

 

NOTES:

X = Distance from “0” to beginning of floor coverage.

Y = Distance from “0” to end of floor coverage.

Length of floor coverage = Y - X.

Z = Distance from “0” to the point where the air velocity drops below 50 feet (15.2M) per minute.

Throws listed are with standard louvers facing one direction and fully open. Throw pattern changes with louver angle, 2-way louver direction, and or optional 4-way louvers.

Throw (feet and meters)

Mounting Height

(feet)

Standard Louvers

Throw (feet)

60° Degree Nozzle

 

 

30° Degree Nozzle

 

 

 

 

 

 

 

 

 

 

 

 

 

X

Y

Z

X

Y

Z

X

Y

Z

 

 

 

 

 

 

 

 

 

 

 

20

 

5

55

134

40

90

146

70

125

158

30

 

8

53

121

44

86

133

76

119

145

40

 

12

49

109

47

81

120

N/A

N/A

N/A

50

 

17

45

96

N/A

N/A

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

Mounting Height

(Meters)

Standard Louvers

Throw (meters)

60° Degree Nozzle

 

 

30° Degree Nozzle

 

 

X

Y

Z

X

Y

Z

X

Y

Z

 

 

 

 

 

 

 

 

 

 

 

6.1

 

1.5

16.8

40.8

12.2

27.4

44.5

21.3

38.1

48.2

9.1

 

2.4

16.2

36.9

13.4

26.2

40.5

23.2

36.3

44.2

12.2

3.7

14.9

33.2

14.3

24.7

36.6

N/A

N/A

N/A

15.2

5.2

13.7

29.3

N/A

N/A

N/A

N/A

N/A

N/A

Form RZ-NA-I-LDAP, P/N 207733 (Rev 2), Page 7

Page 7
Image 7
Thomas & Betts LDAP 1200 warranty Heater Location, Mounting Height Heater Throw - All Models