Toro 212 manual Control Dial Positions continued, Controller Components

Models: 212

1 36
Download 36 pages 2.29 Kb
Page 6
Image 6
3 - Control Dial Positions (continued)

Controller Components

3 - Control Dial Positions (continued)

SEASON ADJUST Manual background – Enables the run time of all zones in a program to be simultaneously increased or decreased in 10% increments.

OFF Manual background – Shuts off and prevents all automatic and manual watering activity.

RAIN DELAY Manual background – Enables all watering operations to be delayed from 1 to 7 days.

4 - Program Select Switch Three-position slide switch used to select watering program A, B or C during the programming procedures and manual operation.

5 - 12 or 24-Hour Clock Selector Jumper – Removing this jumper selects 24-hour (military time) clock mode. Jumper installed selects 12-hour clock mode.

6 - Run Delay Selector Jumper– Removing this jumper selects a 15-second delay period before a station begins watering. Jumper installed provides a 2-second delay.

7 - Odd/Even Day Schedule Selector Jumper – Removing this jumper enables an Odd/Even water- ing day schedule to be selected.

8 - Fuse – 0.75 Amp, 250V Fast Blow fuse.

9 - Battery Charger Switch – Controls the battery charging circuit. Switch positions provided for Alkaline and rechargeable batteries.

10 - Rain Sensor Control Switch – Controls the sensor input circuit. Switch positions provided for sensor

4circuit On and Off.

11 - Sensor Connection Terminals Snap-in connec- tors for connection of an (optional) Toro Rain Switch.

12 - Common Connection Terminal Snap-in wire connector for the valve common wire.

13 - Pump/Master Valve Connection Terminal Snap-in wire connector for a pump start relay or master valve.

14 - Transformer Connection Terminals Snap-in connectors for the plug-in transformer wires.

15 - Plug-In Station Control Module – Each control module provides snap-in connectors for two station control valve power wires. Up to six modules can be installed.

16 - 9-Volt Battery – The battery maintains the con- troller memory if the transformer power is discon- nected. Either Alkaline or rechargeable battery types can be installed.

17Power Supply – A Plug-in transformer supplies 24 V a.c. power to the controller.

(Domestic transformer version shown.)

18- Remote Control Receiver Jack – Modular jack provided for connection of the optional Toro Remote Control receiver cable.

(Refer to the instructions provided with the remote control device for installation and operation details.)

Page 6
Image 6
Toro 212 manual Control Dial Positions continued, Controller Components