Reelmaster 4000–D Page 5 – 11 Electrical System (Rev. A)
J7
J8
4
ALARM TEST
6
2
3
3
4
5
6
1
2
3
TO MAIN
HARNESS
3
4
1
2
SILENCE
ALARM
ALARM
1
J20
J2
(+)
(–)
P5
P2
5
4
12
J21
J22
J23
J24 J3 J4
J6
J5
TO LIGHT
CLUSTER
5
SILENCE
ALARM
J1
1
2
34
5
6
ALARM
P3
P4
TO MAIN
HARNESS
J9
J10
J11
J12
J13 J14
J15
J16
P1
TO LIGHT
CLUSTER
J19
J18 J17
SWITCH
SWITCH
Light Cluster Harness DrawingReelmaster 4000–D
WIRE IDENTIFICATION
LABEL COLOR ROUTE
W66. YEL/BLU P5–4, J16
W67. GRN P5–3, J14
W68. GRN/WHT 1P5–2, J15
W69. YEL P5–1, J13
W70. YEL/BLU J16, P2–5
W71. GRN J14, P2–4
W72. GRN/WHT J15, P2–1
W73. YEL J13, P2–2
W74. BLK/WHT P2–3, P2–6
W75. BLK/WHT P2–3, P1–3
W76. BLK/WHT P2–6, P3–1
W77. BLK/WHT P1–3, P1–6
W78. RED 1P4–4, J10
W79. WHT P4–2, J12
W80. BLU 1P4–3, J11
W81. BRN P4–1, J9
W82. RED J10, P1–4
W83. WHT J12, P1–5
W84. BLU J11, P1–1
W85. BRN 1J9, P1–2
W86. BLK/WHT 1P1–6, J1
W87. GRY 1P3–5, J2
W88. ORG 1P3–2, J5
W89. GRN/BLK 1J17, J18
W90. GRN/BLK 1J18, J19
W91. GRN/BLK J19, J20
W92. GRN/BLK 1J20, J3
W93. ORG 1J21, J22
W94. ORG 1J22, J23
W95. ORG 1J23, J24
W96. ORG J8, J24
W97. ORG J8, J5
W98. YEL J6, P3–3
W99. GRY 1J2, J7
W100. GRY J7, P3–4
W101. BLK/WHT J1, P4–6
W102. BLK J4, P4–5
Electrical