Reelmaster 4000–D Page 4 – 41 Hydraulic System
Meter (Gerotor) End Disassembly
1. Clamp unit in vise, meter end up. Clamp lightly on
edges of mounting area, see Fig. 26. Use protective ma-
terial on vise jaws. Housing distortion could result if jaws
are over–tightened.
2. Remove 5/16” cap screws.
3. Remove end cap.
4. Remove seal from end cap.
5. Remove meter. Be careful not to drop star.
6. Remove seal from meter.
Figure 26
Figure 27
Figure 28
Hydraulic