Reelmaster 4000–D
Page 4 – 50
Hydraulic System
23. Install drive spacer(s), when used, in meter, see
Fig. 49.
24. Install 3” diameter seal in end cap.
25. Install end cap on gerotor, align holes.
26. Install 7 dry cap screws with new seal washers in
end cap. Pre–tighten screws to 150 inch pounds, ten
torque screws to 275 inch pounds in sequence shown
in Fig. 50.
Figure 49
Figure 50