Troubleshooting Procedures
2-16 [CONFIDENTIAL] Qosmio F60 Series Maintenance Manual (960-796)
Check 1 Convert the DC IN icon blink pattern into the hexadecimal error code and compare it to the tables below. Then go to Check 2. Table 2-3 Error codeError code Where error occurs
1*h DC Power (AC Adapter)
2*h Main battery
3:h 2nd battery
4*h S3V output
5*h E5V output
6*h E3V output
7*h 1R5-B1 output
8*h 1R05-P1V output
9*h PPV output
A*h 1R5-PGV output (10G)
1R05-P1V output (10)
B*h PTV output
C*h PGV output(10G)
IGD-PGV output(10)
D*h SURS-PP output
E*h 1R5-PGV output(10G)
1R05-P1V output(10)
F*h -
DC power supply (AC adapter) Error code Meaning
10h AC Adapter output voltage is over 20.92V.
11h Common Dock output voltage is over 20.92V..
12h Current from the DC power supply is over 8.00A.
13h Current from the DC power supply is over 0.5A when there is no load.
14h The compensation value of [0A] is not within the limits from design data (±
481mA).