■Setting the feed gap sensor position

8. LOADING THE PAPER

EO1-330019

8. LOADING THE PAPER

Setting the feed gap sensor position

1Move sensor knob A in a horizontal direction so that the Manual backgroundManual backgroundManual backgroundManual backgroundManual background mark on the sensor cover aligns with the centre of the label gap. Remember the number that the centre of the sensor knob A is positioned at. Set sensor knob B to the same position number.

The centtre of the gap

1 2 3 4 5

Sensor Cover

Feed Gap Sensor Position

Manual background Sensor Knob A

Fig. 8-14

2Release the lock lever in the direction indicated by the arrow, and gently lift the sensor cover. NOTE: Lift the sensor cover gently so that it does not touch the ribbon.

3Set the sensor knob B to the same position # of the sensor knob A.

NOTE: Sensor knobs A and B are set to position #3 where the black mark is centred on the label width as a default. Do not change the position of sensor knobs A and B except when changing the sensor detecting position. Be sure to set the sensor knobs A and B to the same position #. Failure to do this may cause a paper feed error and paper end detecting error.

4Draw the label onto the platen. Close the sensor cover and return the lock lever to lock the sensor cover tight.