4. PARAMETER SETTING FUNCTIONS

4. PARAMETER SETTING FUNCTIONS

EO1-33017

4. DIP SWITCH FUNCTIONS

4. PARAMETER SETTING FUNCTIONS

The Following table illustrates settings that are selected only by changing the Printer's PARAMETER settings. This procedure can be found in the Maintenance Manual section of the B-880 Series SERVICE MANUAL under section 6.3. Please Contact your authorized TOSHIBA TEC representative to change the operation panel settings.

Parameter Setting Mode Table

Mode Name

 

Function

SPEED

Baud rate of the serial interface is selected.

DATA LENG.

Data length of the serial interface is selected.

STOP BIT

Stop bit of the serial interface is selected.

PARITY

Parity of the serial interface is selected.

XON+READY

Transmission control mode of the serial interface is selected.

LCD

Language which displays LCD message is selected.

 

 

FORWARD WAIT

Auto forward wait in cut mode is selected. When idle for 3 seconds or

 

more after cutting, the printer automatically feeds the paper 10mm

 

forward.

 

 

 

HEAD UP CUT

Print head up in cut mode is selected. If a back feed is performed when

 

this parameter is ON, it is done while the print head is up. (Available

 

only when the ribbon saving module is installed and the ribbon save

 

mode is ON.)

 

 

 

RIBBON SAVE

The ribbon saving module is selected. Be sure to set this parameter to

 

ON when using the ribbon saving module.

 

 

CODE

The command code out of AUTO, ESC/LF/NUL, or { I } is selected.

RIBBON

Ribbon type either transmissive or non-transmissive is selected.

 

 

SENS POSI

The media sensor position is selected.

 

CENTER: Fixed

 

EDGE:

Movable

 

 

 