5. SET UP PROCEDURE
5.1 REQUIREMENTS FOR OPERATION
5. SET UP PROCEDURE
5.1 REQUIREMENTS FOR OPERATION
The
∙The host computer must have a serial port or centronics parallel port.
∙To communicate with host, either an
(1)
(2)Centronics cable ....... 36 pins
∙To print the format, create the complete program using the interface/communication manual.
■Interface Cables
To prevent radiation and reception of electrical noise, the interface cables must meet the following requirements:
∙Fully shielded and fitted with metal or metalised connector housings.
∙Kept as short as possible.
∙Should not be bundled tightly with power cords.
∙Should not be tied to power line conduits.
■
The serial data cable used to connect the printer to the host computer should be one of the following two types:
NOTE: Use an
|
|
|
|
|
|
|
|
|
|
| |||
Connector to PC | Connector to Printer | ||||||||||||
| Signal |
|
|
|
|
| |||||||
PIN No. |
|
| PIN No. | Signal | |||||||||
1 | N.C. |
|
| ||||||||||
|
| ||||||||||||
2 | RXD |
|
|
|
|
|
| 3 | TXD | ||||
|
|
|
|
|
| ||||||||
3 | TXD |
|
|
|
|
| 2 | RXD | |||||
|
|
|
| ||||||||||
4 | DTR |
|
|
|
|
| 20 | DSR | |||||
|
|
|
| ||||||||||
5 | GND |
|
|
| 7 | GND | |||||||
|
|
| |||||||||||
6 | DSR |
|
|
|
| 6 | DTR | ||||||
|
|
|
| ||||||||||
7 | RTS |
|
|
|
|
|
|
| 4 | CTS | |||
|
|
|
|
|
| ||||||||
8 | CTS |
|
|
|
| 5 | RTS | ||||||
|
|
|
| ||||||||||
9 | N.C. |
|
|
| |||||||||
Housing | Shield |
|
|
| Housing | Shield | |||||||
|
|
|
|
|
|
|
|
|
Connector to PC
PIN No. | Signal |
1Shield
2TXD
3 | RXD |
4 | RTS |
5 | CTS |
6 | DSR |
7 | GND |
20DTR
5.2SETTING UP THE PRINTER
Connector to Printer
PIN No. | Signal |
3 | TXD |
2 | RXD |
20 | DSR |
7 | GND |
6 | DTR |
4CTS
5RTS
Fig.
∙Place the printer on a flat, stable surface.
∙Use a grounded electrical outlet do not use adapter plug.
∙Be sure there is adequate room around the printer for easy operation and maintenance.
∙Keep your work environment static free.