■Cleaning the Cutter Unit

11. GENERAL MAINTENANCE

EO1-33017

11.4 REMOVING JAMMED MEDIA

Cleaning the Cutter Unit

WARNING!

1.Be sure to turn the power off before cleaning the cutter unit.

2.The cutters are sharp and care should be taken not to injure yourself when cleaning.

1.Loosen two screws and remove the cutter cover.

2.Remove the white screw and media guide.

3.Remove the jammed paper and trash.

4.Clean the cutter with dry cloth.

Screw

White Screw

Media Guide

 

Cutter Cover

Swing Cutter

5. Assembling is reverse order of removal.

Cleaning the strip unit

WARNING!

Fixed Cutter

Cutter Unit

Fig. 11-7

Be sure to turn the power off before cleaning the strip unit.

1.Lower the backing paper release bar to remove the jammed media.

2.Clean the strip roller and backing paper holder with ethyl alcohol.

Strip Roller

Backing Paper Holder

Backing Paper Release Bar

Fig. 11-8

11-5