7.5.3. Alarm Recording Settings

Alarm Recording has two Alarm Input modes "EDGE" and "LEVEL" and valid setting items differ depending on each mode.

Alarm Mode set to "EDGE" : Alarm recording time settings are valid. Post-alarm time settings are invalid.

Alarm Mode set to "LEVEL" : Alarm recording time settings are invalid. Post-alarm time settings are valid.

(For more information, Refer to p. 20; "About the Alarm Input Mode.")

• Move the cursor with the ( ) or ( ) key, and change setting values

 

ALARM

REC SETTING

 

 

with the () or (+) key.

 

 

 

ALARM

SETTING

[

VALID ]

• Confirm the setting with the Menu key, and return to the previous

 

 

ALARM

IN MODE

[LEVEL]

screen.

 

 

 

 

PRE – ALARM

[00SEC]

• Each setting item and its setting value and contents are as shown in

 

ALARM

PERIOD

[

1MIN]

 

POST – ALARM

[00SEC]

the table below.

 

 

 

 

 

 

 

 

PICTURE QUALITY

[LEVEL3]

 

 

 

 

 

AUDIO

 

 

[

ON]

 

 

 

 

 

REC INTERVAL

[1/30SEC]

 

 

 

 

 

BUZZER

 

[

ON]

 

 

 

 

 

ALARM

OUT

[DURING

REC]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting Item

Setting Value

 

 

 

Contents

 

 

 

 

 

 

 

 

ALARM SETTING

VALID / VAL REC / INVALID

VALID : Validates alarm settings. (Alarm standby mode)

 

 

 

 

VAL REC : Validates alarm settings only during recording.

 

 

 

 

INVALID : Invalidates alarm settings. (Rejects alarm inputs.)

 

 

ALARM IN MODE

EDGE / LEVEL

EDGE : Performs recording during preset Pre-alarm and Alarm

(Alarm Input Mode)

 

 

Recording periods

 

 

 

 

 

 

 

LEVEL : Performs recording during preset Pre-alarm Recording, Alarm

 

 

 

input, and Post-alarm Recording periods.

 

 

 

PRE-ALARM

00SEC/ 10SEC/ 15SEC/ 20SEC /

Performs retroactive recording to a preset time period before alarm

 

30SEC/ 1MIN/ 2MIN/ 5MIN

activation.

 

 

 

 

 

 

 

 

ALARM PERIOD

10SEC/ 15SEC/ 20SEC/ 30SEC/

Performs recording during a preset alarm input period following alarm

 

1MIN/ 2MIN/ 3MIN/ 4MIN/ 5MIN/

activation when the Alarm Input Mode is set to EDGE. (Refer to p. 20;

 

10MIN

"About the Alarm Input Mode")

 

 

 

 

 

POST-ALARM

00SEC/ 10SEC/ 15SEC/ 20SEC/

Performs recording during a preset Post-alarm recording period following

 

30SEC/ 1MIN/ 2MIN/ 5MIN

the end of alarm activation when the alarm input mode is set to "LEVEL."

 

 

 

PICTURE QUALITY

LEVEL1 / LEVEL2 / LEVEL3 /

LEVEL1 : Angle of view 720 x 240; file size : 64KB (High Picture Quality)

 

LEVEL4 / LEVEL5

LEVEL2 : Angle of view 720 x 240; file size : 40KB

 

 

 

 

 

LEVEL3 : Angle of view 720 x 240; file size : 32KB

 

 

 

 

 

LEVEL4 : Angle of view 720 x 240; file size : 24KB

 

 

 

 

 

LEVEL5 : Angle of view 720 x 240; file size : 16KB

 

 

 

 

 

 

(Standard Picture Quality)

 

 

 

 

 

 

 

 

 

 

AUDIO

ON / OFF

ON:

Records audio sound simultaneously during recording.

 

 

 

 

OFF: Records no audio sound during recording.

 

 

 

REC INTERVAL

1/60SEC / 1/30SEC / 1/15SEC /

Sets the Recording intervals.

 

 

 

 

 

(Recording Interval)

1/10SEC / 1/5SEC / 1/3SEC /

Setting the Disk Mode of Disk Settings to "MIRRORING" limits the

 

1/2SEC / 1SEC /

maximum recording interval to 1/30 second. Even if set to "1/60 SEC", the

 

 

actual recording interval is 1/30 second, and the "1/30 SEC "indication is

 

 

displayed on the screen (C-DR0101, C-DR0105)

 

 

 

BUZZER

ON / OFF

ON:

Sounds a buzzer when an alarm is activated. Pressing the Buzzer

 

 

 

Reset key stops buzzer operation.

 

 

 

 

 

 

OFF: Sounds no buzzer during

alarm activation.

 

 

 

ALARM OUT (Alarm

DURING REC / 1SEC

The Alarm Output terminal shorts to ground during a set period of time

Output Periods )

 

following alarm activation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* The underlined contents are factory-preset values.

19

Page 19
Image 19
Toshiba C-DR0101 instruction manual Alarm Recording Settings, With the or + key, Screen, Table below

C-DR0101 specifications

The Toshiba C-DR0101 is an innovative digital radiography (DR) system designed to enhance imaging capabilities in medical facilities. This advanced system combines Toshiba's cutting-edge technology with user-friendly features to improve diagnostic efficiency and patient care.

One of the standout features of the C-DR0101 is its proprietary flat-panel detector, which provides high-resolution images with exceptional detail. This detector offers a wide dynamic range, maximizing the quality of images captured in various clinical situations, from routine examinations to complex procedures. The system is equipped with advanced image processing algorithms that enhance image clarity and reduce noise, ensuring that healthcare professionals have access to accurate diagnostics.

The C-DR0101 is designed with ease of use in mind. Its intuitive user interface streamlines workflow, allowing radiologists and technicians to quickly select imaging protocols and adjust settings as needed. This user-friendly design not only saves time but also minimizes the learning curve for new operators. The system's compact footprint allows for easy integration into existing radiology departments, making it a versatile choice for various healthcare environments.

In terms of technology, the C-DR0101 utilizes wireless connectivity, which allows for more flexible positioning of the detector and reduces clutter in the exam room. This wireless feature also facilitates the seamless transfer of images to the hospital's information system, enabling quick access to patient data and images for timely decision-making.

Another key characteristic of the C-DR0101 is its enhanced patient safety features. The system is designed to minimize radiation exposure while still delivering high-quality images. This is achieved through advanced dose management technologies and customizable exposure settings tailored to the specific needs of each patient. This focus on patient safety aligns with the goals of modern healthcare to prioritize the well-being of patients while delivering effective diagnostic imaging solutions.

The Toshiba C-DR0101 stands out in the field of digital radiography through its combination of advanced imaging technology, user-friendly design, and commitment to patient safety. As healthcare continues to evolve, systems like the C-DR0101 play a crucial role in ensuring that medical professionals can provide prompt and accurate care.