Toshiba DEV002Z-1 manual ACC1, THR2, ACC2 THR Alarm EMG, Ready, St/Run St/ Run

Models: DEV002Z-1

1 37
Download 37 pages 45.56 Kb
Page 17
Image 17
Bit 5

E6581281 f

3.4.5.3. Instance 100/150 - Toshiba Specific (4 bytes, parameter f830 = 2)

Byte

Bit 7

Bit 6

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

DC braking

ACC1/

PI off

THR2

Preset

Preset

Preset

Preset

ACC2

Speed4

Speed3

Speed2

Speed1

 

 

 

 

1

Command

Frequency

Reset trip

Emergency

Free run (ST)

Run/stop

Forward/

Jog

 

link *

link *

 

stop

 

 

Reverse

 

2

 

 

Drive Reference Speed Hz (Low byte) **

 

 

3

 

 

Drive Reference Speed Hz (High byte) **

 

 

Fig. 5 Output Instance 100 Layout

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

DC braking

ACC2

PI

 

THR 2

-

ALARM

EMG

FL

 

(VF2+tH2)

(fc91)

 

 

 

 

 

 

 

 

1

 

READY

READY

 

Emergency

 

 

Forward /

 

-

without

with

 

Free run (ST)

Run/Stop

Jog

 

 

ST/RUN

ST/ RUN

stop

 

 

Reverse

 

 

 

 

 

 

 

 

2

 

 

 

Drive Actual Speed Hz (Low byte)

 

 

3

 

 

 

Drive Actual Speed Hz (High byte)

 

 

Fig. 6 Input Instance 150 Layout

* Bit 14 and 15 of the instance 100 byte 0 are defined as follows.

Bit 15 (Command link) .... When “0” is set, the other command does not work except bit 12 and 13,

Run/Stop is according to setup of the parameter cmod.

Bit 14 (Frequency link) ... When “1” is set, bytes 2 and 3 are enabled. When “0” is set, Drive Reference

Speed is according to setup of the parameter fmod.

** Drive Reference Speed is set up by 0.01Hz unit and the hexadecimal number.

For example, when "Frequency reference" is set up to 60Hz, since the minimum unit is 0.01Hz, 60 / 0.01 = 6000 = 0x1770 (Hex.)