Toshiba DEV002Z-1 E6581281 f 6.16. FC91 Alarm code, Function Over current alarm, Over heat alarm

Models: DEV002Z-1

1 37
Download 37 pages 45.56 Kb
Page 27
Image 27

E6581281 f

3.4.6.16. FC91 (Alarm code)

bit

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Function

0

1

Note

Over current alarm

Normal

 

Under alarm

“c” blinking

Inverter over load alarm

Normal

 

Under alarm

“l” blinking

Motor over load alarm

Normal

 

Under alarm

“l” blinking

Over heat alarm

Normal

 

Under alarm

“h” blinking

Over voltage alarm

Normal

 

Under alarm

“p” blinking

Under voltage of main power

Normal

 

Under alarm

-

(Reserved)

-

-

-

Under current alarm

Normal

 

Under alarm

-

Over torque alarm

Normal

 

Under alarm

-

OLr alarm

Normal

 

Under alarm

-

Cumulative run-time alarm

Normal

 

Under alarm

-

(Reserved)

-

-

-

(Reserved)

-

-

-

(Reserved)

-

-

-

Stop after instantaneous power off

-

 

Dec., Under stop

Refer to f256 value

Stop after LL continuance time

-

 

Dec., Under stop

Refer to uvc value

3.4.6.17. FD06 (Input TB Status)

bit

TB Name

Function (Parameter)

0

1

0

F

Input TB Function select

1 (f111)

 

 

1

R

Input TB Function select

2 (f112)

 

 

2*

ST

Input TB Function select

3 (f113)

 

 

3

RES

Input TB Function select

4 (f114)

 

 

4

S1

Input TB Function select

5 (f115)

 

 

5

S2

Input TB Function select

6 (f116)

 

 

6

S3

Input TB Function select

7 (f117)

 

 

7

S4

Input TB Function select

8 (f118)

OFF

ON

8

L1

Input TB Function select

9 (f119)

 

 

9

L2

Input TB Function select 10 (f120)

 

 

10

L3

Input TB Function select 11 (f121)

 

 

11

L4

Input TB Function select 12 (f122)

 

 

12

L5

Input TB Function select 13 (f123)

 

 

13

L6

Input TB Function select 14 (f124)

 

 

14

L7

Input TB Function select 15 (f125)

 

 

15

L8

Input TB Function select 16 (f126)

 

 

*This function is reserved in VF-PS1.

3.4.6.18. FD07 (Output TB Status)

bit

TB Name

Function (Parameter)

0

1

0

OUT1

Output TB Function select

1 (f130)

 

 

1

OUT2

Output TB Function select

2 (f131)

 

 

2

FL

Output TB Function select

3 (f132)

 

 

3

OUT3

Output TB Function select

4 (f133)

 

 

4

OUT4

Output TB Function select

5 (f134)

 

 

5

R1

Output TB Function select

6 (f135)

OFF

ON

6

OUT5

Output TB Function select

7 (f136)

 

 

7

OUT6

Output TB Function select

8 (f137)

 

 

8

R2

Output TB Function select

9 (f138)

 

 

9

R3

Output TB Function select 10 (f168)

 

 

10

R4

Output TB Function select 11 (f169)

 

 

11 - 15

-

-

 

-

-

- 26 -

Page 27
Image 27
Toshiba DEV002Z-1 E6581281 f 6.16. FC91 Alarm code, Function Over current alarm, Inverter over load alarm, Over heat alarm