(1. 3. 3) Changing the setting in PW SNR mode
Move up down |
| Select the desired | ||||||
by pushing |
| value by pushing | ||||||
MENU UP, DOWN |
| DATA UP, DOWN | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
MODE | E.TRG |
E.TRG | PW SNR |
TRG.P |
|
PART | OFF |
<MODE = E.TRG E.TRG = PW SNR>
•Sutter mode MANU, SS, E.TRG
•E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR, RR
•Input trigger pulse setting at PW SNR and PW SR
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
•Partial scanning switch OFF/40fps/50fps/60fps/70fps/80fps/90fps/ E40fps/E50fps/E60fps/E70fps/E80fps/E90fps
(a) Changing the polarity of inputting trigger pulse setting
1Move the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing the partial scanning setting
1Move the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select the mode by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD cameras become: fixed pattern noise, white pixels, etc.
18