Toshiba ik-tf7u RR Reset restart, Long Term Exposure, Input Timing Chart Example

Models: ik-tf7u

1 36
Download 36 pages 38.43 Kb
Page 29
Image 29

( 5 ) RR (Reset restart)

Input of an external reset-restart signal (CC4 of the DIGITAL terminal: External VD input) permits one screen of information to be output at an arbitrary timing.

(5. 1) Long Term Exposure

When a sufficient sensitivity is not obtained with the normal operation conditions or capturing the trial of a moving subject is desired, the reset-restart function allows high-sensitivity images by extending the exposure time. To achieve this, please input from an external source a VD signal that has an expanded VD pulse and VD pulse interval.

(5. 2) Input Timing Chart Example

External HD IN

External VD IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V reset

 

 

V reset

 

 

 

 

 

 

 

About 1H

 

 

About 1H

(Internal VD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exposure period

 

 

 

Exposure period

 

 

 

 

 

 

 

 

Exposure period

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGB data (video interval image)

FVAL

LVAL,

DVAL

1 frame

1 frame= 796H (Partial scanning OFF)

 

 

580H (Partial scanning 40fps)

 

465H (Partial scanning 50fps)

 

387H (Partial scanning 60fps)

 

332H (Partial scanning 70fps)

 

290H (Partial scanning 80fps)

 

258H (Partial scanning 90fps)

External VD interval: more than 1 frame

29

Page 29
Image 29
Toshiba ik-tf7u instruction manual RR Reset restart, Long Term Exposure, Input Timing Chart Example