( 7 ) Returning to factory settings
All the settings can be returned to the factory default status (preset status).
(1)If characters are displayed on the screen, press the [DISP] button to disable the character display.
(2)Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(3)The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed for approx. 1 second.
7. 3 Synchro. Scan Operation
The shutter speed can be set by the horizontal scanning period (1H) or by the frame.
( 1 ) Setting by 1H
1H/796H ~ 795H/796H stands for the setting by the 1H and the shutter speed can be set by the 1H (43.05 ∝s). When operating Partial Scannig, the number’s listed below can be used for setting.
Partial scanning OFF | 1H/796H ~ 795H/796H |
40fps, E40fps | 1H/580H ~ 579H/580H |
50fps, E50fps | 1H/465H ~ 464H/465H |
60fps, E60fps | 1H/387H ~ 386H/387H |
70fps, E70fps | 1H/332H ~ 331H/332H |
80fps, E80fps | 1H/290H ~ 289H/290H |
90fps, E90fps | 1H/258H ~ 257H/258H |
( 2 ) Setting by the frame
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.
(Internal VD)
RGB data (video interval image)
FVAL
LVAL,
DAVL
n
n+1
(4FRM setting)
24