( 7 ) Returning to factory settings

All the settings can be returned to the factory default status (preset status).

(1)If characters are displayed on the screen, press the [DISP] button to disable the character display.

(2)Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.

(3)The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed for approx. 1 second.

7. 3 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H) or by the frame.

( 1 ) Setting by 1H

1H/796H ~ 795H/796H stands for the setting by the 1H and the shutter speed can be set by the 1H (43.05 s). When operating Partial Scannig, the number’s listed below can be used for setting.

Partial scanning OFF

1H/796H ~ 795H/796H

40fps, E40fps

1H/580H ~ 579H/580H

50fps, E50fps

1H/465H ~ 464H/465H

60fps, E60fps

1H/387H ~ 386H/387H

70fps, E70fps

1H/332H ~ 331H/332H

80fps, E80fps

1H/290H ~ 289H/290H

90fps, E90fps

1H/258H ~ 257H/258H

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.

The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.

(Internal VD)

RGB data (video interval image)

FVAL

LVAL,

DAVL

n

n+1

(4FRM setting)

24

Page 24
Image 24