5 PIPING AND DRAIN HOSE INSTALLATION

5 PIPING AND DRAIN HOSE INSTALLATION

Piping and drain hose forming

*Apply thermal-insulation for both refrigerant pipe and drain hose surely so that no dewing generates inside of the equipment. (Use polyethylene foam for insulating material.)

Rear right

Rear left

Bottom left

Left

Bottom right

Die-cutting

front panel slit

Changing drain hose

Piping preparation

Right

1. Die- cutting front panel slit

For piping work at the left side, cut off the left slit for notching of the front panel. (A knife will produce flaws on the panel, so use nippers.)

2. Changing drain hose

For piping work at the left side, lower left side, and left back side, it is necessary to change the drain hose and drain cap.

How to remove the drains cap

Clip drain cap by needle- nose pliers, and pull out.

How to fix the drains cap

1)Insert hexagonal wrench (Ø4mm) in a center head.

How to install the drain hose

Firmly insert drain hose connecting part until hitting on a heat insulator.

Heat insulator Piping and drain hose forming

Drain hose

2) Firmly insert drains cap.

4 mm

No gap

Insert a hexagon wrench (4 mm)

Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Application causes deterioration and drain leakage of the plug.

CAUTION

Firmly insert the drain hose and drain cap; otherwise, water may leak.