Toshiba MMK-AP0092H In case of right or left piping, Left- hand connection with piping

Models: MMK-AP0092H MMK-AP0072H MMK-AP0122H

1 29
Download 29 pages 40.58 Kb
Page 11
Image 11
In case of right or left piping

In case of right or left piping

After scribing slits of the front panel with a knife or a marking-off pin, cut them with a pair of nippers or an equivalent tool.

In case of bottom right or bottom left piping

After scribing slits of the front panel with a knife or a marking- off pin, cut them with a pair of nippers or an equivalent tool.

Slit

Slit

Left- hand connection with piping

Bend the connecting pipe so that it is laid within 43mm above the wall surface. If the connecting pipe is laid exceeding 43mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use a spring bender so as not to crush the pipe.

Bend the connection pipe within a radius of 30 mm.

To connect the pipe after installation of the unit (figure)

43 mm

(To the fore front of flare)

270mm

 

Liquid side

170mm

 

Gas

side

 

 

 

 

Outward form of indoor unit

R 30 mm (Use polish polyethylene core or the like for bending pipe.)

Use the handle of screwdriver, etc.

NOTE

If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.

After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them.

CAUTION

Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear- leftward piping, bind the auxiliary pipes ( two) only with facing tape.

Indoor unit

Auxiliary pipes

Connecting cable

Installation plate In case of bottom right or bottom left piping

Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit.

Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double- taping at the joint, moreover, seal the joint with the vinyl tape, etc.

Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material.)

When bending a pipe, carefully do it, not to crush it.

8

Page 11
Image 11
Toshiba MMK-AP0092H, MMK-AP0122H In case of right or left piping, In case of bottom right or bottom left piping