6 INDOOR UNIT FIXING

6 INDOOR UNIT FIXING

1.Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks.

2.Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate.

3.While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked up on the installation plate.

For detaching the indoor unit from the installation plate, pull the indoor unit toward you while pushing its bottom up at the specified parts.

Hook here

1

7 DRAINAGE 1 Installation plate

2

Hook

Press

(unhook)

Push Push

7 DRAINAGE

1. Run the drain hose sloped downwards.

NOTE

Hole should be made at a slight downward slant on the outdoor side.

2.Put water in the drain pan and make sure that the water is drained out of doors.

3.When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe.

Do not form the drain hose

Do not rise the drain hose. into a wavy shape.

50mm or more

Do not put the

Do not put the

drain hose end

drain hose end in

into water.

the drainage ditch.

 

Shield pipe

 

Drain hose

Inside the

Extension drain hose

 

room

 

 

 

CAUTION

Arrange the drain pipe for proper drainage from the unit.

Improper drainage can result in dew- dropping.

This air conditioner has the structure designed to drain water collected from dew, which forms on the back of the indoor unit, to the drain pan.

Therefore, do not store the power cord and other parts at a height above the drain guide.

Space for pipes

Wall

Drain guide

9