4 CUTTING A HOLE AND MOUNTING INSTALLATION PLATE

4 CUTTING A HOLE AND MOUNTING INSTALLATION PLATE

Cutting a hole

In case of installing the refrigerant pipes from the rear:

1.Decide the hole position for piping at 100mm from the arrow mark ( Cutting a hole ) on the installation plate and drill a hole with Ø65mm at a slight downward slant toward outdoor side.

The center of the pipe hole is above the arrow.

Pipe hole

65 mm

100 mm

NOTE

When drilling a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately.

Mounting the installation plate

107 127.5

Hook

For installation of the indoor unit,

use the paper pattern in the accessory parts.

170

 

 

 

85

 

 

 

 

 

 

1

 

 

Hook

Installation

 

Thread

plate

Pipe hole

Pipe hole

Hook

5 Mounting screw

 

 

 

Indoor unit

Weight

 

When the installation plate is directly mounted on the wall

1.Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit.

2.To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in the above figure.

3.Install the installation plate horizontally in the wall.

CAUTION

When installing the installation plate with a mounting screw, do not use the anchor bolt hole.

Otherwise the unit may fall down and result in personal injury and property damage.

NO

OK NO

Anchor bolt

GOOD

GOOD

5mm dia. hole

Projection Mounting the installation plate 15mm or less

7 Mounting screw Ø4 × 25 When the installation plate is directly mounted on the wall

OK NO Clip anchor (local parts)

CAUTION

Failure to firmly install the unit may result in personal injury and property damage if the unit falls.

In case of block, brick, concrete or similar type walls, make 5mm dia. holes in the wall.

Insert clip anchors for appropriate mounting screws.

NOTE

• Secure four corners and lower parts of the installation plate with 4 to 6 mounting screws to install it.