The lamp used is UHP 100/120W, driven by the ballast, this lamp/ballast combination is made by Philips enables to select lamp power for 100W or 120W by mechanical slide switch.
Do not replace the lamp with other model, a reflector which focuses the lamp b eam is designed for DLP use, with light tunnel application. Different lamp may not have right specification or lamp life may be much different. The lamp for previous model, P500DL, is different from the P503DL lamp. To avoid such confusion, the lamp connector has different shape so that other lamp will not fit.
3.Power Supply PCB
The power supply consists of two sections, Power Factor Control and
Incoming AC is rectified and supplied to the PFC converter, where the voltage and current phases are matched, thus resulting power factor becomes 1.
The output of the PFC circuit is 380V DC and this is supplied to the main
The outputs of the main DC
Also, +12V which is connected to the fans and +5V for micro processor are separately prepared.
4.Lamp Ballast PCB
The Philips® 100/120W UHP lamp is driven by Philips ballast, power supply. The input voltage is 380V DC and high voltage trigger which is about 20kV pulse to ignite while lamp start period and lamp supply voltage is given to continue to its discharge by about AC50V, plus
5.RS232C Control PCB
RS232C control signal or/and remote control from optional CT90000 are accepted, if both are connected CT90000 has priority over RS232C communication line.
RS232C parallel cables need to use.
6.Video PCB (option)
Accepts PAL/NTSC/SECAM composite video signal and has a buffered output for
more movement delays may result.
In such occasion, Video output to next video input, video loop through may results better picture by less delay composed.
Appendix-1
P503DL control board LED status
| POWER | FAN | LAMP | Blink time |
| |
|
|
|
|
|
| |
POWER OFF | OFF | OFF | OFF |
|
| |
STANBY |
|
|
|
|
| |
ON (red) | OFF | OFF |
|
| ||
|
|
| ||||
Preparation | ON (green) | ON (green) | OFF |
| Before Lamp lights | |
|
|
|
|
| ||
|
|
|
|
|
| |
POWER ON | ON (green) | ON (green) | ON (green) |
| After Lamp lights up | |
|
|
|
|
| ||
|
|
|
|
|
| |
Normal | ON (green) | ON (green) | ON (green) |
|
| |
FAN STOP |
|
|
|
|
| |
ON (green) | Blink | OFF | 0.2 SEC | Lamp will shutdown | ||
| ||||||
|
| (green) |
|
|
| |
|
|
|
|
|
| |
LAMP cannot | ON (green) | ON (green) | OFF |
|
| |
light |
|
|
|
|
| |
|
|
|
|
|
|
33