Manuals
/
Brands
/
Household Appliance
/
Air Conditioner
/
Toshiba
/
Household Appliance
/
Air Conditioner
Toshiba
RAS-09LAV-UL, RAS-09LKV-UL, RAS-12LAV-UL, RAS-12LKV-UL
4. CONSTRUCTION VIEWS
1
16
114
114
Download
114 pages, 5.67 Mb
4. CONSTRUCTION VIEWS
FILE NO.
SVM-10019
4-1.
Indoor Unit
– 16 –
Contents
<High Wall, Heat Pump Type
<Heat Pump Type
Feburary
CONSTRUCTION VIEWS
WIRING DIAGRAM
REFRIGERANT CYCLE DIAGRAM
EXPLODED VIEWS AND PARTS LIST
1. SAFETY PRECAUTIONS
New refrigerant air conditioner installation
DANGER
WARNING
Page
2. SPECIFICATIONS
2-2.Operation Characteristic Curve
<Cooling
<Heating
2-3.Capacity Variation Ratio According to Temperature
<Heating
3. REFRIGERANT R410A
3-1.Safety During Installation/Servicing
3-2.Refrigerant Piping Installation
3-2-1.Piping Materials and Joints Used
1.Copper Pipes
Table 3-2-1Thicknesses of annealed copper pipes
Thickness in. (mm)
Outer diameter (mm)
R410A
R22
Fig. 3-2-1Flare processing dimensions
Table 3-2-3Dimensions related to flare processing for R410A
Outer
A in. (mm)
Nominal
Table 3-2-6Flare and flare nut dimensions for R22
Fig. 3-2-2Relations between flare nut and flare seal surface
2.Flare Connecting Procedures and Precautions
Table 3-2-7Tightening torque of flare for R410A [Reference values]
Tightening torque
3-3-1.Required Tools
3-4.Recharging of Refrigerant
bit by bit
Fig. 3-4-1Configuration of refrigerant charging
3-5-1.Materials for Brazing
3-5-2.Flux
3-5-3.Brazing
Never use gas other than Nitrogen gas
4. CONSTRUCTION VIEWS
4-2.Outdoor Unit
5. WIRING DIAGRAM
5-2. RAS-12LKV-UL /RAS-12LAV-UL
6. SPECIFICATIONS OF ELECTRICAL PARTS
7. REFRIGERANT CYCLE DIAGRAM
RAS-12LKV-UL / RAS-12LAV-UL
INDOOR UNIT
OUTDOOR UNIT
7-2.Operation Data
8. CONTROL BLOCK DIAGRAM
MICRO-COMPUTERBLOCK DIAGRAM
Unit Outdoor
MCC5009 (P.C.B)
Assembly) (Inverter
9. OPERATION DESCRIPTION
9-2.Operation Description
9-3.Auto Restart Function
9-4.Remote Controller and Its Fuctions
Remote controller
Indoor unit
Outdoor unit
Page
Indication
Fan speed
Page
Page
Outdoor temp
Page
Page
Page
Page
Page
Page
Page
Page
J201
Page
Page
9-3-1.How to Cancel the Auto Restart Function
9-3-3.Power Failure During Timer Operation
9-4.Remote controller and Its functions
9-4-1.Parts name of remote controller
9-4-2.Operation of remote control
1. ONE-TOUCH
2.AUTOMATIC OPERATION
4.DRY OPERATION (COOLING ONLY)
5.Hi-POWEROPERATION
6.ECO OPERATION
Note:
7.TEMPORARY OPERATION
9. PRESET OPERATION
10.AUTO RESTART OPERATION
Setting
11.QUIET OPERATION
12. COMFORT SLEEP OPERATION
9-4-3.Name and Functions of Indications on Remote Controller
10. INSTALLATION PROCEDURE
10-2.Installation
10-1-2.Optional installation parts
Part
Q'ty
Code
10-2-2.Accessory and installation parts
Others Name
10-2-3.Installation/Servicing Tools
10-3-1.Installation Location
Remote controller
10-3-2.Cutting a Hole and Mounting the
mounting Plate
Cutting a hole
When the installation plate is directly mounted on the wall
10-3-3.Electrical Work
10-3-4.Wiring Connection
How to connect the connecting cable
10-3-5.Piping and Drain Hose Installation
Piping and drain hose forming
How to remove the drain cap
How to remove the drain hose
How to attach the drain cap
How to attach the drain hose
In case of right or left piping
In case of bottom right or bottom left piping
Left-handconnection with piping
10-3-6.Indoor Unit Installation
10-3-7.Drainage
10-4-1.Installation Location
Precautions for adding refrigerant
10-4-2.Refrigerant Piping Connection
Flaring
10-4-2.Wiring Connection
10-4-3.Electrical Work
Stripping length of the Power supply cord and Inter connecting cable
10-5.EVACUATING
10-6.SYSTEM REQUIREMENTS
10-7.OTHERS
10-7-5.Remote Controller A or B Selection Setting
Remote controller A or B selection
Remote controller A- B selection
Remote controller B Setup
Note :
11. HOW TO DIAGNOSE THE TROUBLE
< Discharging method
11-1-1.Confirmation of Power Supply
11-1-2.Confirmation of Power Voltage
11-1-3.Operation Which is not a Trouble (Program Operation)
11-2.Primary Judgment
11-3.Judgment by Flashing LED of Indoor Unit
NOTES :
11-4-1.How to Use Remote Controller in Service Mode
11-4-2Caution at Servicing
Page
Page
Page
Page
11-5.Judgement of Trouble by Every Symptom
11-5-1.Indoor unit (Including remote controller)
(1) Indoor unit is not operated
(RAS-09LKV-UL)
( RAS-12LKV-UL)
(2)
Operation
(3) Only the indoor motor fan does not operate <Primary check
<Check procedure
Page
Page
(4)
<Cause
<Inspection procedure
(For DC fan motor in RAS-12LKV-UL)<Cause
Page
11-5-2.Wiring Failure (Interconnecting and Serial Signal Wire)
11-6.Check Code 1C (Miswiring in indoor/outdoor units) and 1E
<Check procedure
1C1E
11-7.How to Diagnose Trouble in Outdoor Unit
Page
11-8.How to Check Simply the Main Parts
11-8-1.How to check the P.C. board (Indoor unit)
(1)Operating precautions
(2)Inspection procedures
a.Main P.C. board part:
11-8-2.P .C . Board Layout
( RAS-12LKV-UL)
[1] Sensor characteristic table
11-8-4.OutdoorUnit
11-8-5.Checking Method for Each Part
11-9.How to Simply Judge Whether Outdoor Fan Motor is Good or Bad
1.Symptom
2.Cause
3.How to simply judge whether outdoor fan motor is good or bad
12. HOW TO REPLACE THE MAIN PARTS
<How to assemble the front panel
<How to assemble the electric parts box
Page
<Caution at assembling
Page
<Caution at reassembling
12-2.Microcomputer
12-3.Outdoor Unit
1. Detachment
2. Attachment
Page
Page
…Side cabinet 1. Side cabinet (right)
2.Side cabinet (left)
Page
Page
•Attachment
13. EXPLODED VIEWS AND PARTS LIST
13-2.Indoor Unit
13-3.Outdoor Unit (RAS-09LAV-UL)
13-4.Outdoor Unit (RAS-12LAV-UL)
13-5.P.C. Board Layout
TOSHIBA CARRIER (THAILAND) CO.,LTD