CAUTION
•Bind the auxiliary pipes (two) and connecting cable with facing tape tightly.
In case of leftward piping and
| Indoor unit |
Auxiliary pipes | Connecting |
| |
| cable |
Installation |
|
plate |
|
Fig.
•Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit.
•Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid
•Since condensation can result in machine performance trouble, be sure to insulate both connecting pipes. (Use polyethylene foam as insulating material.)
•When bending a pipe, be careful not to crush it.
10-3-6. Indoor Unit Installation
1.Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks.
2.Swing the indoor unit to right and left to confirm that it is firmly hooked on the installation plate.
3.While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate.
Pull the indoor unit toward you to confirm that it is firmly hooked on the installation plate.
1 Hook here
1Installation plate
2 | Push (unhook) | |
Hook | ||
|
Fig.
•For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing the bottom up at the specified places.
Push Push
Fig.
FILE NO.
10-3-7. Drainage
1. Run the drain hose at a downward sloped angle.
NOTE :
•Hole should be made at a slight downward slant on the outdoor side.
Do not rise the drain hose. | Do not form the drain hose | |
| into the waved shape. | |
2 in. |
|
|
(50 mm) |
|
|
or more |
|
|
Do not put the | Do not put the drain | |
drain hose end | hose end in the | |
into water. |
| drainage ditch. |
Fig.
2.Put water in the drain pan and make sure that the water is being drained outside.
3.When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe.
Shield pipe
Drain hose Inside the room | Extension drain hose |
Fig.
CAUTION
Install the drain pipe for proper drainage.
Improper drainage can result in water dripping inside the room.
This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan.
Therefore, do not locate the power cord and other parts at a high place than the drain guide.
Wall
Drain guide
Space for pipes
Fig.