When cooling does not operate

Troubleshooting Guide

Trouble 3

When cooling does not operate

 

 

 

 

 

Turn on Main Power

 

 

 

Operate "Cooling Mode( 34Ceiling Cassette Air ConditionerManual background )" by setting the desired temperature of the remote controller to at least 1°C(1.8ºF) below room temperature.

When in Air Circulation Mode, Compressor/Outdoor Fan is stopped.

Check the sensor for indoor temperature is attached as close as to be effected by the temperature of Heat Exchanger(EVA).

When the sensor circuit for indoor temperature and connector are in bad connection or are not engaged, Compressor/Outdoor Fan is stopped.

• Check the indoor temperature sensor is disconnected or not(About 10k/ at 25°C(77°F)).

Check Relay(RY - COMP) for driving compressor.

When the power(About AC208V-230V) is applied to the connecting wire terminal support transferred to compressor, PWB Ass'y is normal.

Check the circuit related to the relay.

Check point

COMP ON

COMP OFF

 

 

 

Between two pin of DC

Below DC 1V

About DC12V

part in relay for COMP

(app)

 

 

 

 